Excell 150 Series User Manual

Excell 150 Series User Manual

Precision balance

Advertisement

B
H
3
B
H
3
P
r
e
c
i
s
i
o
n
B
a
l
a
n
c
e
P
r
e
c
i
s
i
o
n
B
a
l
a
n
c
e
U
s
e
r
M
a
n
u
a
l
U
s
e
r
M
a
n
u
a
l
©
Excell Precision Limited 2017. All rights reserved Worldwide.
The information contained herein is the property of Excell Precision Limited and is supplied
without liability for errors or omissions. No part may be reproduced or used except as
authorised by contract or other written permission.
The copyright and the foregoing
restriction on reproduction and use extend to all media in which the information may be
embodied.

Advertisement

Table of Contents
loading

Summary of Contents for Excell 150 Series

  • Page 1 © Excell Precision Limited 2017. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission.
  • Page 2: Table Of Contents

    EXCELL PRECISION CO., LTD. Table of Contents PRECAUTIONS FOR USE ......................3 PREPARING TO USE THE BALANCE ..................3 PROTECTION IN THE TRANSPORTATION................4 CHAPTER ONE PRODUCT FEATURES ..................5 1-1 Features ..........................5 1-2 Specifications ........................6 1-3 Plastic Shield Installation & Dimension ................8 1-4 Description of Power Supply ....................
  • Page 3 EXCELL PRECISION CO., LTD. 3-1-8 Auto Unit Weight Averaging Setting ..........24 3-1-9 Zero Tracking Range Setting ............25 3-2 Weight Calibration and Gravity Compensation ..........26 3-2-1 External Weight Calibration ............. 27 3-2-2 Gravity Compensation ..............28 3-2-3 Restore to the Default Setting ............
  • Page 4: Precautions For Use

    EXCELL PRECISION CO., LTD. PRECAUTIONS FOR USE Thank you for purchasing BH3 precision balance. To enable you to use this balance correctly, we suggest that you read these precautions carefully. 1. It must be prevented from getting wet. If it gets wet, please wipe it dry with a cloth. If there is something wrong with the machine, please contact your supplier.
  • Page 5: Protection In The Transportation

    EXCELL PRECISION CO., LTD. PROTECTION IN THE TRANSPORTATION Before using the BH3 Precision Balance, please read the following illustrations to take off the protection screw. For the maintenance of this machine, install the protection screw before the transportation to avoid any damage on the sensitive components.
  • Page 6: Chapter One Product Features

    EXCELL PRECISION CO., LTD. CHAPTER ONE PRODUCT FEATURES 1-1 Features 1/30,000 and 1/60,000 display resolution available.  Auto calibration.  Weighing, counting and percentage modes.  Setting the usable units from 13 weighing units.  Default unit selectable, Auto-off timer setting, Backlight mode setting, Digital ...
  • Page 7: Specifications

    EXCELL PRECISION CO., LTD. 1-2 Specifications External resolution: 1/30000 150 Series 300 Series 600 Series 1500 Series 3000 Series 150 0.005 300  0.01 600  0.02 1500  0.05 3000  0.1 150 0.05 300  0.1 600  0.2 1500 ...
  • Page 8 EXCELL PRECISION CO., LTD. External resolution: 1/60000 300 Series 600 Series 1200 Series 3000 Series 300  0.005 600  0.01 1200  0.02 3000  0.05 300  0.05 600  0.1 1200  0.2 3000  0.5 1500  0.05 3000 ...
  • Page 9: Plastic Shield Installation & Dimension

    EXCELL PRECISION CO., LTD. 1-3 Plastic Shield Installation & Dimension BH3 Series (02024013) ZSME300000289...
  • Page 10: Description Of Power Supply

    EXCELL PRECISION CO., LTD. 1-4 Description of Power Supply Power supplies 1. 4 pcs of UM-2 dry batteries 2. 9V DC 300mA adaptor Power Consumption 1. The power consumption is around DC 0.5 mA (standby mode). 2. The power consumption is around DC 30~35 mA (system + load cell).
  • Page 11: Display

    EXCELL PRECISION CO., LTD. 1-6 Display Stable Low battery Accumulation indicator indicator Zero Minus sign Tare Mode Unit display 1-7 Keyboard Function : Off key. Press the key to switch the balance off. 線粗1.5mm : Function key. Press the key to select different operation modes: weighing mode, MODE counting mode, and percentage mode.
  • Page 12: Chapter Two Operation Instructions

    EXCELL PRECISION CO., LTD. CHAPTER TWO OPERATION INSTRUCTIONS 2-1 Zero Function →0← When the display shows weight value without anything placed on the platter, press the to re-zero the balance. The zero indicator 0 is on, indicating a center-of zero gross weight condition.
  • Page 13: Weighing Mode

    EXCELL PRECISION CO., LTD. 2-3-1 Weighing Mode Ⅰ. Units Selection Press the key to select the desired weighing unit. UNITS  There are 13 units available: g, ct, lb, oz, dr, GN, ozt, dwt, MM, tl.J, tl.T, tl.H and t.
  • Page 14: Counting Mode

    EXCELL PRECISION CO., LTD. 2-3-2 Counting Mode Sampling 1. Press the MODE key to select the Counting mode and the display shows pcs. 2. Press the key to select a sample size from 10, 20, 50, 100, or 200 pcs.
  • Page 15: Percentage Mode

    EXCELL PRECISION CO., LTD. 2-3-3 Percentage Mode Sampling key to select the “Percentage” mode and the display shows 1. Press the MODE 2. Press the key to select 100.0% or 100.00%. 3. Place enough sampling weight on the platter and press the key.
  • Page 16: Chapter Three Function Settings

    EXCELL PRECISION CO., LTD. CHAPTER THREE FUNCTION SETTINGS  MODE MODE Press key for 3 seconds or hold keys together, the balance enters the function setting mode, and the display shows UNIT Please refer to page  16 ~ 25 ...
  • Page 17: General Function Setting

    EXCELL PRECISION CO., LTD. 3-1 GENERAL FUNCTION SETTING  There are nine functions settings available Press UNIT    Back to the previous level UNIT     First unit setting UNIT     Operation units setting UNIT ...
  • Page 18: First Unit Setting

    EXCELL PRECISION CO., LTD. 3-1-1 First Unit Setting  The default setting is “g” UNIT Use the key to select the    UNIT unit in cycle, and press the key to confirm   the setting.  UNIT There are 13 weighing units available for selection: ...
  • Page 19: Operation Units Setting

    EXCELL PRECISION CO., LTD. 3-1-2 Operation Units Setting UNIT There are 13 weighing units available for selection. Use the or the key to switch    between ON and OFF for each unit.  The default setting for all 13 units are “ON”...
  • Page 20: Auto-Off Timer Setting

    EXCELL PRECISION CO., LTD. 3-1-3 Auto-Off Timer Setting  The default setting is “ 0 ”. UNIT   UNIT Use the or the key to select    one from the four modes:  UNIT Press the key to confirm and the setting ...
  • Page 21: Backlight Mode Setting

    EXCELL PRECISION CO., LTD. 3-1-4 Backlight Mode Setting  The default setting is “ AUTO ” ( The auto backlight is on) Auto backlight  When there is weight on the platter (the value is larger than  10 divisions), or when any key is pressed, the backlight is on.
  • Page 22: Noise Filter Setting

    EXCELL PRECISION CO., LTD. 3-1-5 Noise Filter Setting Set a parameter in 01 to 02, according to the environment where the balance is positioned.  Please select “ 01 ”, when operation environment is unstable.  Please select “ 02 ”, when operation environment is stable.
  • Page 23: Forward Zero Display Setting

    EXCELL PRECISION CO., LTD. 3-1-6 Forward Zero Display Setting  The default setting is “ 1 ” ( 1d, d=division ) UNIT   UNIT Use the or the key to select    a zero display range. ...
  • Page 24: Backward Zero Display Setting

    EXCELL PRECISION CO., LTD. 3-1-7 Backward Zero Display Setting  The default setting is “ 2 ” ( 2d, d=division ) UNIT Use the or the key to select UNIT      a proper parameter.  Press the key to confirm the setting.
  • Page 25: Auto Unit Weight Averaging Setting

    EXCELL PRECISION CO., LTD. 3-1-8 Auto Unit Weight Averaging Setting  The default setting is “ Yes” (Automatic Unit Weight Calibration) UNIT Use the or the key to select    “Yes” or “No.” Press the key to confirm the setting.
  • Page 26: Zero Tracking Range Setting

    EXCELL PRECISION CO., LTD. 3-1-9 Zero Tracking Range Setting Zero Tracking Range Setting  3/4 d ) ( default value: UNIT Press key to select parameter.     1/4 d  2/4 d  3/4 d  1 d ...
  • Page 27: Weight Calibration And Gravity Compensation

    EXCELL PRECISION CO., LTD. 3-2 Weight Calibration and Gravity Compensation Press the UNIT   UNIT    UNIT      Weight Calibration  Gravity Compensation  Restore to the default setting  When set as “YES” for the external Gravity calibration function, function is available.
  • Page 28: External Weight Calibration

    EXCELL PRECISION CO., LTD. 3-2-1 External Weight Calibration The display shows the calibration weight Press the (equal to the full capacity) and the weight unit. The first digit flashes.  The calibration weight can be Ensure the platter is on the modified if necessary.
  • Page 29: Gravity Compensation

    EXCELL PRECISION CO., LTD. 3-2-2 Gravity Compensation Press the to show the history data 1 sec UNIT The display shows the latest modification done before    1 sec UNIT The display shows the 5 modification done before ...
  • Page 30: Restore To The Default Setting

    EXCELL PRECISION CO., LTD. 3-2-3 Restore to the Default Setting Press the UNIT   UNIT    UNIT     Press the  Return to upper level  Restore to the default setting in external weight calibration and gravity compensation ...
  • Page 31: Rs232 Serial Interface Setting

    EXCELL PRECISION CO., LTD. 3-3 RS232 SERIAL INTERFACE SETTING Press the UNIT   UNIT     Return to upper level UNIT     Transmission Mode Setting UNIT  Baud Rate Setting     Communication Protocol...
  • Page 32: Transmission Mode Setting

    EXCELL PRECISION CO., LTD. 3-3-1 Transmission Mode Setting  The default setting: “ ” UNIT  UNIT  Use the or the key to select    UNIT from the 4 modes available:   Press the key to confirm the setting.
  • Page 33: Baud Rate Setting

    EXCELL PRECISION CO., LTD. 3-3-2 Baud Rate Setting  The default setting: “ ” UNIT   UNIT   UNIT Use the or the key to select    from the 7 baud rates:  UNIT Press the key to confirm the setting.
  • Page 34: Communication Protocol Setting

    EXCELL PRECISION CO., LTD. 3-3-3 Communication Protocol Setting  The default setting: “ ” UNIT   UNIT   UNIT Use the or the key to set the    parameter  UNIT   Press the key to confirm the setting.
  • Page 35: Output Format Setting

    EXCELL PRECISION CO., LTD. 3-3-4 Output Format Setting  The default setting is “ ” UNIT   UNIT Use the or the key to select UNIT      format mode. Press the key to confirm the setting.
  • Page 36: Re-Zero Range Setting

    EXCELL PRECISION CO., LTD. 3-3-5 Re-zero Range Setting  The default setting: “ ”  Setting range is from 00 ~ 99 Input the parameter 00 ~ 99  Upward digit selecting (0-9)  UNIT  Downward digit selecting (9-0) ...
  • Page 37: Weight Range Setting

    EXCELL PRECISION CO., LTD. 3-3-6 Weight Range Setting  ” (The weight range change will not be defined) The default setting:“  Weight Range can be set 00 ~ 99. And “ 00 ” is default. When range is over set value, and Stable Transmission or Manual Transmission Modes is set the value will print out.
  • Page 38: Date & Time Display Setting

    EXCELL PRECISION CO., LTD. 3-3-7 Date & Time Display Setting  This function is available with RTC card.  Time will need to be reset when the balance is out of battery with its adaptor unplugged. Please replace the battery before proceeding to reset the time.
  • Page 39: Date & Time Setting

    EXCELL PRECISION CO., LTD. 3-3-8 Date & Time Setting  This function is available with RTC card.  Time will need to be reset when the balance is out of battery with its adaptor unplugged. Please replace the battery before proceeding to reset the time.
  • Page 40: Appendix I Unit Conversion Table

    EXCELL PRECISION CO., LTD. APPENDIX I UNIT CONVERSION TABLE  MET.CARAT  0.2 g  AVOIRDUPOIS POUND  453.59237 g oz  AVOIRDUPOIS OUNCE  28.349523125 g dr  AVOIRDUPOIS DRAM  1.7718451 g GN  GRAIN (U.K) 0.06479891 g ozt ...
  • Page 41: Appendix Ii Full Capacity Table

    EXCELL PRECISION CO., LTD. APPENDIX II FULL CAPACITY TABLE External Resolution: 1/30000 150 Series 300 Series 600 Series 1500 Series 3000 Series 150.045 300.09 600.18 1500.45 3000.9 150.45 300.9 601.8 1504.5 3009 750.45 1500.45 3000.9 7504.5 15004.5 754.5 1504.5 3009...
  • Page 42 EXCELL PRECISION CO., LTD. External Resolution: 1/60000 3000 Series 300 Series 600 Series 1200 Series 300.045 600.09 1200.18 3000.45 300.45 600.9 1201.8 3004.5 1500.45 3000.45 6000.9 15004.5 1504.5 3004.5 6009 15045 0.66018 1.32045 2.64045 6.6018 0.6618 1.3245 2.6445 6.618 10.5018 21.1045...
  • Page 43: Appendix Iii Rs232 Bi-Direction Format

    EXCELL PRECISION CO., LTD. APPENDIX III RS232 BI-DIRECTION FORMAT General Format Gross + SP 1 6 SP SP SP g 6 SP SP c Tare 6 SP SP k Overload O L + SP SP SP SP SP SP SP SP SP SP SP SP...
  • Page 44 EXCELL PRECISION CO., LTD. RS232 OUTPUT FORMAT Format 1 (RS1 04 is set form 1 ) DATA HEAD1 HEAD2 SIGN UNITS HEAD1 (3 byte) Stable Unstable Overload HEAD2 (3byte) Gross Weight Net Weight SIGN (1byte) Positive weight Negative weight DATA (8byte)
  • Page 45 EXCELL PRECISION CO., LTD. Format 2 (RS1 04 is set form 2 ) CR LF SIGN DATA UNITS SIGN (1byte) Positive weight Negative weight DATA (8byte) 8 BYTES including the decimal point UNITS(4byte) CR,LF (2byte)  Total length of transmission is 15 bytes ( 1 + 8 + 4 + 2 = 15 )
  • Page 46 EXCELL PRECISION CO., LTD. Format 3 (RS1 04 is set form 3 with option card RTC) Weight Mode CR LF CR LF CR LF CR LF CR LF CR LF CR LF CR LF Counting Mode CR LF CR LF...
  • Page 47 EXCELL PRECISION CO., LTD. Format 4 (RS1 04 is set form 4) Weight Mode CR LF CR LF CR LF CR LF CR LF CR LF Counting Mode CR LF CR LF CR LF CR LF CR LF CR LF...

This manual is also suitable for:

300 series600 seriesBh31500 series3000 series

Table of Contents