  • Page 2 Note: This is not meant to be a complete manual, but a guide to help you get started with your system. For more detailed instructions on operating the Ultium system and its features please refer to the complete Ultium EMG User Manual, also included with your system. 1 System Unboxing The Ultium Insole system is packed within a reinforced padded box for storage and protection during transport.
  • Page 3: Hardware Installation

    Insole Smart Lead Quick Start Guide 2 Hardware Installation 2.1 Hardware Setup Instructions Step 1 Insert the USB-B (smaller) end of the USB cable (CBL2) into the USB connector on the rear of the Ultium Receiver (880). Insert the opposite end of the USB cable into an available USB port on the computer.
  • Page 4 Insole Smart Lead Quick Start Guide Step 5 Connect the Insole SmartLead (826) to the Ultium Sensor (810). The Ultium Sensor will blink purple after the SmartLead is detected. Step 6 Connect the Insole Sensor (826x) to the Insole SmartLead (826) (Rev A)
  • Page 5 1. Insert the MR3 USB flash drive into the PC 2. A menu will automatically pop up 3. Click on the Noraxon installation file and follow the Wizard’s instructions 4. After installation, an icon will be created on the desktop 3.2 Companion Software Activation...
  • Page 6: Configuring The Hardware

    Within the ‘Settings Tab’, select the desired collection Sampling Rate. If using MyoSync, check the Use Noraxon MyoSync checkbox (see the Ultium EMG User Manual for more information). Select a RF Network from the RF Network list. In most cases the default “1” will work. However, if using multiple Ultium systems they must be placed on separate networks.
  • Page 7 Insole Smart Lead Quick Start Guide Step 5 Click the Sensors Tab. Place all Ultium Sensors into the chargers and attach the chargers to the Ultium Receiver. Attach the Insole Smart Leads to the Ultium sensor. Click Detect Sensors in Charger to load all serial numbers into the MR3 software.
  • Page 8 Insole Smart Lead Quick Start Guide 4 Zone Anterior/Posterior Each zone shown by the red outline is an average of the sub-zones. Example Heel = average of the Medial and Lateral heel zones 4 Zone Combined Each zone shown by the red outline is an average of the sub-zones.
  • Page 9: Recording A Measurement

    Insole Smart Lead Quick Start Guide 5 Recording a Measurement Step 1 Within the Home screen, click on the myoMUSCLE module icon. Create a New Subject Select New Configuration. Step 2 Insert the devices to be used for the measurement into the configuration by dragging a device in from the list of Available devices.
  • Page 10 Insole Smart Lead Quick Start Guide Step 3 Select to Calibrate (normalize) the insole pressure data to static standing pressure. Continue to the next step by selecting Measure. Step 4 After checking for normal signal display, you are ready to record a measurement. Select Record at the top left of the screen and begin your protocol.
  • Page 11: Viewing A Record

    Insole Smart Lead Quick Start Guide 6 Viewing a Record To view a previously recorded record, select the Database tab. Records are organized by Project and Subject name. Double click on the record of interested to open the record in the Viewer tab. 7 Further Use Features of MR3 There are many additional features built within MR3.
  • Page 12 Insole Smart Lead Quick Start Guide 9 Insole Care and Cleaning Extra care must be taken when cleaning the insoles. • Clean with isopropyl alcohol or disinfectant wipes. • Dampen the surfaces and do not allow solution into the vent holes. Each insole has 5 vent holes which must remain open and free of any debris.