Advertisement

READ THIS MANUAL BEFORE USING THIS PRODUCT
Important Safety Information Inside
Keep this manual in a safe location
for future reference
O P E R A T I N G I N S T R U C T I O N S
HIVAMAT
200 Personal
B Y
GA02040US
M A N U F A C T U R E D B Y

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHUDO HIVAMAT 200 Personal and is the answer not in the manual?

Questions and answers

Summary of Contents for Physiomed CHUDO HIVAMAT 200 Personal

  • Page 1 READ THIS MANUAL BEFORE USING THIS PRODUCT Important Safety Information Inside Keep this manual in a safe location for future reference O P E R A T I N G I N S T R U C T I O N S HIVAMAT ™...
  • Page 2 Distribution, reproduction and translation of the software and its documentation (or excerpts thereof) are prohibited without the prior written consent of PHYSIOMED ELEKTROMEDIZIN AG. PHYSIOMED ELEKTROMEDIZIN AG reserves the right to change the software and associated data as well as the documentation without notice. All other rights reserved.
  • Page 3: Table Of Contents

    Table of Contents PHYSIOMED ELEKTROMEDIZIN AG Table of Contents Chapter 1 Important Safety Instructions ......1 1.1 Indications for Use ....... . . 2 1.2 Contraindications .
  • Page 4 Table of Contents PHYSIOMED ELEKTROMEDIZIN AG Chapter 6 Indications ........16 Chapter 7 Individual Programs .
  • Page 5: Chapter 1 Important Safety Instructions

    The treatment card must not be copied, and any attempt to reproduce it or read out the data will invalidate it. PHYSIOMED ELEKTROMEDIZIN AG accepts no responsibility for damage in- curred in this way.
  • Page 6: Indications For Use

    1 Important Safety Instructions PHYSIOMED ELEKTROMEDIZIN AG 1.1 Indications for Use WARNING The instrument must only be operated by medical practicioners who have undergone special training. Use by unqualified personnel or consumers bears the risk of serious injury. The function of HIVAMAT ™...
  • Page 7: Precautions

    1 Important Safety Instructions PHYSIOMED ELEKTROMEDIZIN AG 1.4 Precautions (a) Caution should be used for patients with suspected or diagnosed heart problems. (b) Caution should be used for patients with suspected or diagnosed epilepsy. (c) Caution should be used: •...
  • Page 8: Chapter 2 Introduction

    2 Introduction PHYSIOMED ELEKTROMEDIZIN AG Chapter 2 Introduction With HIVAMAT ™ 200 Personal you have acquired an extremely versatile deep oscillation system. The instrument will only show its true potential, however, if you are well informed about its functions. For this reason, carefully read these Operating Instructions and familiarise yourself with the use of the instrument.
  • Page 9: Instrument Overview

    2 Introduction PHYSIOMED ELEKTROMEDIZIN AG 2.3 Instrument Overview Front Panel Legend Display Card Reader Data Selector Power Adaptor Socket Ports Control Light Bottom Symbols in the Display Battery Indicator (refer to Battery Operation on page 9) Indications HIVAMAT ™ 200 Personal...
  • Page 10: Instrument Description

    2 Introduction PHYSIOMED ELEKTROMEDIZIN AG Individual Treatment Settings Menu (refer to Settings on page 21) Button Back 2.4 Instrument Description CAUTION During the charging procedure, the patient must neither be connected with the titanium neutral element, nor with the hand applicator! HIVAMAT ™...
  • Page 11: Chapter 3 Controls And Indicators

    3 Controls and Indicators PHYSIOMED ELEKTROMEDIZIN AG Chapter 3 Controls and Indicators The design of HIVAMAT ™ 200 Personal allows for easy operation, in combination with a variety of functions. Because of its small size, the instrument is very easy to transport. It has been designed for oper- ation also outside of therapy rooms, and is fed by a rechargeable battery for that reason.
  • Page 12: Ports <3

    3 Controls and Indicators PHYSIOMED ELEKTROMEDIZIN AG 3.1.3 Ports <3> The Ports <3> serve to connect the supplied cables (Ref. no. 00261 and 00262) for the hand applicator and the adhesive electrode or Titanium neutral element with the instrument. You can find instructions on how to connect the cables in section to prepare the applicator on page 15.
  • Page 13: Chapter 4 Instrument Operation

    4 Instrument Operation PHYSIOMED ELEKTROMEDIZIN AG Chapter 4 Instrument Operation 4.1 Battery Operation CAUTION The instrument contains a Lithium ion battery. Don't expose it to excessive heat or open fire. The battery can only be replaced by an authorized service partner. Never open the instrument yourself to replace the battery.
  • Page 14: Economy Mode

    4 Instrument Operation PHYSIOMED ELEKTROMEDIZIN AG NOTICE Rechargeable batteries discharge over an extended period, even if the instrument is switched off. This self-discharge process cannot be prevented; the following instructions must therefore be considered to guarantee the battery a long service life.
  • Page 15: Preparations And Start-Up

    4 Instrument Operation PHYSIOMED ELEKTROMEDIZIN AG 4.2 Preparations and Start-Up How to Start up the Instrument Insert the therapy card with the chip side facing down into the Card Reader <4>. Important If the card is defective or incompatible, a respective error message will be displayed.
  • Page 16: Cable Check

    4 Instrument Operation PHYSIOMED ELEKTROMEDIZIN AG 4.4 Cable Check If you should have the impression that a cable is defective during treatment, you can check it using the in- strument. How to Check a Cable Select a therapy and set the intensity to 100% using the Data Selector <2>.
  • Page 17: Therapy Card

    CAUTION The treatment card must not be copied, and any attempt to reproduce it or read out the data will invalidate it. PHYSIOMED ELEKTROMEDIZIN AG accepts no responsibility for damage in- curred in this way. All programs available for HIVAMAT ™...
  • Page 18: Chapter 5 Treatment Preparation

    5 Treatment Preparation PHYSIOMED ELEKTROMEDIZIN AG Chapter 5 Treatment Preparation WARNING The instrument must only be operated by medical practicioners who have undergone special training. CAUTION Before each treatment, adjust the intensity to match the respective conditions and pay atten-...
  • Page 19: Monitoring Notes

    5 Treatment Preparation PHYSIOMED ELEKTROMEDIZIN AG How to prepare the applicator Plug the connection cables HIVAMAT ™ 200 (Ref. no. 00261) for the hand applicator and for the Titanium neutral element into the Ports <3>. Connect the Titanium neutral element with the other end of the cable and let the patient grip it. Al- ternatively, you can attach it on any part of the patient's body.
  • Page 20: Chapter 6 Indications

    6 Indications PHYSIOMED ELEKTROMEDIZIN AG Chapter 6 Indications With HIVAMAT ™ 200 Personal you can perform treatments according to preset indications which are stored together with the corresponding therapy parameters on the therapy card. For each displayed indica-tion you can refer to the recommended therapy instructions. Each indication features an image of a body region to be treated, which shows the preferable direction of treatment.
  • Page 21 6 Indications PHYSIOMED ELEKTROMEDIZIN AG Indications - Treatment Parameters Rotate the Data Selector <2> to return to the first page. Press the Data Selector <2> two times so that the intensity is shown underlined in blue. (10) Rotate the Data Selector <2> to select the desired intensity. The current treatment phase is indic- ated by a black dot.
  • Page 22: Chapter 7 Individual Programs

    7 Individual Programs PHYSIOMED ELEKTROMEDIZIN AG Chapter 7 Individual Programs Individual programs allow you to adjust therapy parameters such as duty cycle and frequency. You have two options for individual treatment: • INDIVID Sequence • INDIVID Manual How to perform an INDIVID SEQUENCE treatment...
  • Page 23 7 Individual Programs PHYSIOMED ELEKTROMEDIZIN AG Click again on INDIVID to get to the second page. Click again on INDIVID. You can now rotate the Data Selector <2> to select the current treatment duration, the duty cycle (e.g. 3:1), the lower frequency (e.g. 50 Hz), the upper frequency (e.g. 125 Hz) and the treatment duration of the three phases.
  • Page 24: Appendix A Reference Information

    ™ 200 service centers authorized by PHYSIOMED ELEKTROMEDIZIN AG. Any repairs performed by an authorisedauthorized service center must be accompanied by written certification, describing the nature and extent of the repairs undertaken, as applicable with details regarding changes to nominal operating values or the operational range. The certification must also contain the date performed, the name of the repair company and the signature of the service person.
  • Page 25: Training

    Reference Information PHYSIOMED ELEKTROMEDIZIN AG cording to national, local and facility rules, regulations and procedures. Environment Protection Symbol A.5 Training Training is given in the course of the introduction to the instrument. Should the need arise however, continued training can be provided by a medical device consultant. Please contact Chudo.
  • Page 26: Technical Data

    Reference Information PHYSIOMED ELEKTROMEDIZIN AG Click to confirm, and then click the brightness symbol. Rotate the Data Selector <2> until the parameter has the desired value. Click the symbol. You return to the menu. The new settings are immediately active.
  • Page 27: Manufacturer

    Reference Information PHYSIOMED ELEKTROMEDIZIN AG A.9 Manufacturer PHYSIOMED ELEKTROMEDIZIN AG Hutweide 10 91220 Schnaittach Germany A.10 Technical Support When you have questions concerning HIVAMAT ™ 200 Personal please refer to the following email or call the phone number below: KISMET HOLDINGS GROUP/CHUDO...
  • Page 28: Appendix B Scope Of Delivery And Accessories

    For safety reasons, the instrument is to be used exclusively with original accessories. The use of other manufacturers' accessories is at the user's risk! The manufacturer excludes any liability associated with the use of accessories which are not supplied through PHYSIOMED ELEKTROMEDIZIN AG. B.1 Scope of Delivery HIVAMAT ™...
  • Page 29: Self-Care Kit

    Scope of Delivery and Accessories PHYSIOMED ELEKTROMEDIZIN AG B.2.1 Self-Care Kit Ref.-No. Designation Quantity 00379 Applicator handhold 00382 Titanium Neutral Element 00261 Connection Cable 00381 Oscillator head Ø 5 cm 00386 Oscillator head Ø 9,5 cm HIVAMAT ™ 200 Personal...
  • Page 30: Index

    Index PHYSIOMED ELEKTROMEDIZIN AG function check Index general notes accessories additional supplied handheld applicator ambient temperature hypersensitivity application to electrostatic fields batteries implants handling electronic battery important user information brightness indications indicators function cable check individual programs card reader infections...
  • Page 31 Index PHYSIOMED ELEKTROMEDIZIN AG repairs selftest 11 , 15 service settings skin diseases infectious start-up technical data therapeutic fields therapy card thromboses untreated training treatment tuberculosis active venous diseases acute warnings warranty weight HIVAMAT ™ 200 Personal...

Table of Contents