Spray height controller fast 120' passive roll (29 pages)
Summary of Contents for Norac UC4+ SPRACOUPE 4000 Series
Page 1
Spray Height Controller SPRACOUPE 4000 Series Installation Manual Improving the competitiveness of Industry and Agriculture through Precision Measurement...
Page 2
NOTICE NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical...
TABLE OF CONTENTS INTRODUCTION ..............................1 GENERAL SYSTEM DESCRIPTION ........................2 PARTS LISTS ................................. 3 INSTALLATION PROCEDURE .......................... 7 ..........................7 XISTING SYSTEM CHECK ............................7 PEED ........................9 ...
INTRODUCTION Congratulations on your purchase of the NORAC UC4+ Spray Height Controller. This system is manufactured with top quality components and is engineered using the latest technology to provide operating features and reliability unmatched for years to come. When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.
However, NORAC cannot boom movement will need to be done guarantee all parts fit as intended due to the first. Once the hydraulics have been variations of the sprayer by the manufacturer.
PARTS LISTS The parts that come with your UC4+ System are listed in Table 1. The item number on the left side of this table references each part. Please ensure that all parts in your kit are present before proceeding with your installation. Table 1 –...
Page 7
FACE P - PIPE The use of dielectric grease is not recommended on any NORAC electrical connections. To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. Permatex...
Page 8
The parts that come with your UC4+ Spray Height Control system are shown below in their general installation configuration. Figure 2 – UC4+ Spray Height Control Components...
INSTALLATION PROCEDURE 4.1 E XISTING SYSTEM CHECK It is necessary to check the existing system’s 2. Set your sprayer at field working RPM on functionality before installing the UC4+ Spray the throttle and mark this value in Table 4. Height Control system. You will need a stopwatch or a 1.
Page 11
Table 4 – Boom Test Record (WITHOUT UC4+ Spray Height Control system) Working RPM: Trial #1 Trial #2 Trial #3 Avg Time Boom [Sec] [Sec] [Sec] [Sec] Left UP Left DOWN Right UP Right Down Main UP Main DOWN Roll CW Roll CCW Table 5 –...
Operator’s Manual (M01) implications. To assemble the breakaway sensor bracket: 4. Mount the NORAC UC4+ ultrasonic sensor a) Assemble the bolt and nut into the (E02) into the sensor brackets. The sensors collar. should be oriented forward (ahead) of the b) Grease the bottom edge of the collar boom (see Figure 6 and Figure 8).
Page 13
number on the left hand side General mounting rules for UC4+ proceeding to the largest serial ultrasonic wing sensors: number on the right hand side a) In its lowest position, the sensor mouth (Figure 11). must be 9 inches or more from the 5.
Page 14
Figure 9 – Wing Sensor Mounting (80ft Boom) Figure 10 – Wing Sensor Mounting (60ft Boom) Apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. Figure 11 – Sensor Serial Number Installation Location...
Figure 12 – Mounting the Roll Sensor to the Roll Sensor Mounting Bracket 2. Attach the roll sensor and roll sensor bracket to the boom, near the NORAC valve block using the provided cable ties. 3. Attach the temperature probe on the roll sensor to the side of the NORAC valve block, using the provided 3/8”...
4.5.1 Valve Assembly 1. On a clean surface remove all plastic plugs Figure 15 – Valve Block Assembly from the NORAC hydraulic Valve (V01) (Figure 14). Figure 14 – NORAC Valve Block 2. Install the orifices (F05) into the "B" ports with the notch facing outward as shown in Figure 15.
4.5.2 Valve Mounting 1. Mount the NORAC valve (V01) on the If using bolts, the bolts should thread sprayer using the valve mounting bracket. into the valve block at least 3/8". The valve mounting holes are drilled 2. Screw short side of the threaded rods into and tapped 3/8 NC-1"...
(F02) between the steel line and the hose (Figure 18). 4. Connect the 90 degree fittings of hoses H02 to the “A” and “B” ports of the NORAC block (Figure 17). Route hoses H02 from the NORAC valve block to the tee fittings (F02) (Figure 18).
Page 19
NORAC Pressure Line (H03) NORAC Tank Line (H03) SpraCoupe Pressure SpraCoupe Pressure Port Figure 19 – Tank and Pressure Connections...
4.6 E LECTRICAL NSTALLATION 1. Install the UC4+ Control Panel (E01) in the cab of the sprayer. Mount the panel where it will be clearly visible and within easy reach of the operator. A good spot to mount the UC4+ control panel is on the right hand side of the cab to the Roll Over Protection Bar (ROP).
Page 21
Figure 21 – Cable Configurations: E01 and C10 2. Route cable C10 into the cab through the 6. Route the end of C10 with the 2-pin access hole located beneath the dash. There Deutsch and 2-pin weatherpack connectors is a removable access plate beneath the dash to the SpraCoupe Bypass/Jam valve (Figure (on the left, towards the door).
Page 22
C10 at the rear of the sprayer and route to 21. Route the long branches of the sensor the NORAC valve block (Figure 23). branch cable (C02) to the wing sensors and 19. The connectors on the valve cable (C03) connect.
2. If any functions do not work, review the hydraulic and electrical portions of this manual to check for proper installation. If you still have trouble, contact NORAC for assistance. 3. Turn on the power for the UC4+ Control Panel using the switch on the side of its chassis.
5.3 I C10: 44658-93 – UC4+ S OUPE NTERFACE ABLE...
Page 27
Canada NORAC Systems International Inc. CALL TOLL FREE: 1-800-667-3921 (306)664-6711 SHIPPING ADDRESS: 3702 Kinnear Place Saskatoon, SK S7P 0A6 United States NORAC, Inc. CALL TOLL FREE: 1-866-306-6722 (952)224-4142 SHIPPING ADDRESS: 6667 West Old Shakopee Road, Suite 111 Bloomington, MN...
Need help?
Do you have a question about the UC4+ SPRACOUPE 4000 Series and is the answer not in the manual?