Norac UC4+ SPRA-COUPE 7000 Series Installation Manual

Spray height controller

Advertisement

Quick Links

Spray Height Controller
SPRA-COUPE 7000 Series
Installation Manual
Improving the competitiveness of Industry and Agriculture
through Precision Measurement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UC4+ SPRA-COUPE 7000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Norac UC4+ SPRA-COUPE 7000 Series

  • Page 1 Spray Height Controller SPRA-COUPE 7000 Series Installation Manual Improving the competitiveness of Industry and Agriculture through Precision Measurement...
  • Page 2 NOTICE NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION ..............................1     GENERAL SYSTEM DESCRIPTION ........................2     PARTS LISTS ................................. 3     INSTALLATION PROCEDURE .......................... 7     ..........................7     XISTING SYSTEM CHECK ............................7     PEED ........................9  ...
  • Page 4: Introduction

    INTRODUCTION Congratulations on your purchase of the NORAC UC4+ Spray Height Controller. This system is manufactured with top quality components and is engineered using the latest technology to provide operating features and reliability unmatched for years to come. When properly used the system can provide protection from sprayer boom damage, improve sprayer efficiency, and ensure chemicals are applied correctly.
  • Page 5: General System Description

    However, NORAC cannot boom movement will need to be done guarantee all parts fit as intended due to the first. Once the hydraulics have been variations of the sprayer by the manufacturer.
  • Page 6: Parts Lists

    PARTS LISTS The parts that come with your UC4+ System are listed in Table 1. The item number on the left side of this table references each part. Please ensure that all parts in your kit are present before proceeding with your installation. Table 1 –...
  • Page 7 FACE P - PIPE The use of dielectric grease is not recommended on any NORAC electrical connections. To ensure all stainless steel hardware does not gall or seize apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. Permatex...
  • Page 8 The parts that come with your UC4+ Spray Height Control system are shown below in their general installation configuration. Figure 2 – UC4+ Spray Height Control Components...
  • Page 9 Figure 3 – Hydraulic Components...
  • Page 10: Installation Procedure

    INSTALLATION PROCEDURE 4.1 E XISTING SYSTEM CHECK It is necessary to check the existing system’s 2. Set your sprayer at field working RPM on functionality before installing the UC4+ Spray the throttle and mark this value in Table 4. Height Control system. You will need a stopwatch or a 1.
  • Page 11 Table 4 – Boom Test Record (WITHOUT UC4+ Spray Height Control system) Working RPM: Trial #1 Trial #2 Trial #3 Avg Time Boom [Sec] [Sec] [Sec] [Sec] Left UP Left DOWN Right UP Right Down Main UP Main DOWN Roll CW Roll CCW Table 5 –...
  • Page 12: Wing Sensor Installation

    (M01) To assemble the breakaway sensor bracket: implications. a) Assemble the bolt and nut into the 4. Mount the NORAC UC4+ ultrasonic sensor collar. (E02) into the sensor brackets. The sensors b) Grease the bottom edge of the collar should be oriented forward (ahead) of the and the angled tube of the base.
  • Page 13 General mounting rules for UC4+ When installing the UC4+ sensors ultrasonic wing sensors: (E02), start with the smallest serial number on the left hand side a) In its lowest position, the sensor mouth proceeding to the largest serial must be 9 inches or more from the number on the right hand side ground.
  • Page 14 Figure 9 – Spra Coupe Wing Sensor Mounting...
  • Page 15 Apply a light coating of the supplied Permatex Anti-seize grease to all threaded parts upon installation. 3 SENSOR SYSTEM 5 SENSOR SYSTEM Figure 10 – Sensor Serial Number Installation Location...
  • Page 16: Main Lift Sensor Installation

    4.4 M ENSOR NSTALLATION 1. Assemble the main lift sensor bracket (B11) as shown in Figure 11. Sensor Mounting Collar Bracket Tube Bracket Base Sensor Mounting Tab Figure 11 – Main Lift Sensor Bracket 2. The bracket can be mounted to the lowest frame member on the center section of the Figure 13 –...
  • Page 17: Roll Sensor Installation

    4.5 R ENSOR NSTALLATION Mount the roll sensors to the included roll When mounting the roll sensors use the sensor brackets using the machine screws following guidelines and refer to Figure 15. and nylon lock nuts. (Figure 14) a) The smaller the distance between A and B in Figure 15, the better the The roll sensors must be mounted performance will be.
  • Page 18: Boom Roll Sensor Mounting

    * The boom frame roll sensor does not have a temperature probe Figure 16 – Roll Sensor Mounting with Respect to Sprayer Orientation 4.5.1 Boom Roll Sensor Mounting 4.5.2 Chassis Roll Sensor Mounting The boom roll sensor (E04) must be The chassis roll sensor must be mounted to the rotating part of the mounted to a non-rotating part of the...
  • Page 19: Inverted Roll Sensor Mounting

    Figure 17 – Boom and Chassis Roll Sensors Correctly Mounted 4.5.3 Inverted Roll Sensor Mounting towards the right-hand boom. Inverted If desired, the Roll sensor may be mounted mounting may be used to optimize the inverted, so long as the connector exits mounting criteria explained in Section 4.5.
  • Page 20: Hydraulic Installation

    “B” ports. installation. 4.6.1 Valve Assembly 1. On a clean surface remove all plastic plugs from the NORAC hydraulic Valve (V01) (Figure 20). Figure 21 – Valve Block Assembly Figure 20 – NORAC Valve Block 2. Install the 6MJT 6MBR (F02) fittings on the...
  • Page 21: Valve Mounting

    4.6.2 Valve Mounting 1. Mount the NORAC valve (V01) on the sprayer using the valve mounting bracket (B10). 2. As shown in Figure 22, screw short side of the threaded rods into the bottom of the valve block at least 3/8". The valve mounting holes are drilled and tapped 3/8 NC-1"...
  • Page 22: Hydraulic Plumbing

    WARNING! (H03) to run to the “T” fittings (FO4). From this point in the installation the 4. Route the lines from the NORAC valve booms will be inoperative until the block to the “T” fitting which is inserted at electronics are fully installed.
  • Page 23: Electrical Installation

    4.7 E LECTRICAL NSTALLATION 1. Install the UC4+ Control Panel (E01) in the cab of the sprayer. Mount the panel where it will be clearly visible and within easy reach of the operator. A good spot to mount the UC4+ control panel is on the right hand side of the cab to the Roll Over Protection Bar (ROP).
  • Page 24 Figure 26 – Cable Configurations: C01, C04, C10 and C11 2. Remove the electrical panel from the 5. On the left side of the electrical panel right-hand side of the sprayer and locate (Figure 27), there is a knockout. the access hole on the top right hand Remove the knockout and install the side.
  • Page 25 Electrical Panel BOTTOM (view from panel) Grommet w/knockout Access Access Hole Hole TOP (view from cab) 3-PIN Pwr Connection Access Hole Figure 27 – Power Cable Routing (C10) Deutsch connectors. Disconnect these The valve extension cable (C04) is connectors from each other, carefully noting packaged with one GP end not their “mates”.
  • Page 26 13. Route the 4-pin “Sense Line” shroud on C10B through a hole in the armrest, then through a hole near the floor (behind and to the right of the driver’s seat), into the electrical panel (outside). 14. Reconnect the 4-pin Shroud on C10B to the mating 4-pin Tower on C10A to make it one piece again.
  • Page 27 4-pin AMP plug on C01 (Figure 29). C04 at the rear of the sprayer and route to 21. Route the CAN Node cable (C02B) to the where the NORAC valve is located (Figure roll sensors. Follow existing cables and/or 29).
  • Page 28: Completing The Installation

    2. If any functions do not work, review the hydraulic and electrical portions of this manual to check for proper installation. If you still have trouble, contact NORAC for assistance. 3. Turn on the power for the UC4+ Control Panel using the switch on the side of its chassis.
  • Page 29: Electrical Reference - Cable Drawings

    ELECTRICAL REFERENCE – CABLE DRAWINGS 5.1 I C01: 44662B – S ENSOR RUNK ABLE 5.2 I C02: 44668 – S ENSOR RANCH ABLE...
  • Page 30: Item C02B: 44664 - Cable Uc4 Can Node Dual

    5.3 I C02B: 44664 – C UC4 CAN N ABLE 5.4 I C03: 44656D – C ABLE ALVE ARIABLE...
  • Page 31: Item C04: 44651 - Valve Extension Cable

    5.5 I C04: 44651 – V ALVE XTENSION ABLE...
  • Page 32: Item C10: 44650-38 - Power Cable Spra Coupe 7000

    5.6 I C10: 44650-38 – P 7000 <C A> OWER ABLE OUPE ABLE...
  • Page 33: Item C10: 44650-38 - Power Cable Spra Coupe 7000

    5.7 I C10: 44650-38 – P 7000 <C B> OWER ABLE OUPE ABLE...
  • Page 34: Item C11: 44658-15 - Jam Valve Cable Spra Coupe 7000

    5.8 I C11: 44658-15 – J 7000 ALVE ABLE OUPE...
  • Page 35 Canada NORAC Systems International Inc. CALL TOLL FREE: 1-800-667-3921 (306)664-6711 SHIPPING ADDRESS: 3702 Kinnear Place Saskatoon, SK S7P 0A6 United States NORAC, Inc. CALL TOLL FREE: 1-866-306-6722 (952)224-4142 SHIPPING ADDRESS: 6667 West Old Shakopee Road, Suite 111 Bloomington, MN...

Table of Contents