Operating Mode Screen; Flow Rate Information Screen - SANY SY95C Operation And Maintenance Manual

Table of Contents

Advertisement

MACHINE CONTROLS

Operating Mode Screen

2
1
5
6
9
10
Figure 3-16
The Operating Mode screen is used to select a work tool
or the equivalent one-way or two-way flow required:
• Bucket (default) (1)
• Breaker (2)
• Clamshell bucket (3)
• Tilt bucket (4)
• Brush cutter (5)
• Grapple (6)
• Rotary grapple (7)
• Auger (8)
The Operating Mode screen displays the bucket (1) as
the default operation. The auxiliary ports are used for
hydraulic work tools. Select the proper work tool icon
prior to operating it.
• Press the button below the left/right arrow icon (9) to
scroll to and illuminate the selected work tool icon.
• Press the button below the information icon (10) to
access the Flow Rate Information screen. Flow rate
for a work tool can be adjusted on this page. See
"Flow Rate Information Screen" on this page.
4
3
7
8
11
12
0003816
• Press the button below the check mark icon (11) to
confirm the selected work tool.
• Press the button below the return icon (12) to return
to the previous screen.

Flow Rate Information Screen

1
2
3
4
NOTE: Check the work tool operator manual for hydraulic
flow rate information and follow all optional
equipment information and safety precautions.
The Flow Rate Information screen displays the flow rate,
from 0% to 100%, of the hydraulic work tool selected in
the Operating Mode screen:
• RR and RL (1) are for setting right joystick
high-pressure, high-flow auxiliary circuit.
• LR and LL (2) are for setting left joystick
low-pressure, low-flow quick coupler circuit.
• Press the button below the up/down arrow icon (3)
to select the hydraulic flow rate to adjust.
• Press the button below the gear icon (4) to access
the Flow Rate Setting screen.
• Press the button below the check mark icon (5) to
display a service screen that is password-protected.
3-12
5
6
Figure 3-17
SY95C Excavator OMM
0003815

Advertisement

Table of Contents
loading

Table of Contents