NOTE: To prevent damage to the bucket cylinder,
place a wood block (1) between the bucket
cylinder and the trailer floor. Slowly lower
the bucket cylinder onto the wood block.
6. Stop the engine, then turn the key to ON.
7. Operate the joysticks until the pressure inside the
hydraulic cylinders is fully released.
8. Place the hydraulic lockout control lever in the locked
(closed) position.
9. Turn the key to OFF and remove from the key switch.
NOTICE!
• Never turn the battery disconnect switch to OFF while the engine is running. This can
damage the electrical system or cause the machine to operate improperly.
• After machine shutdown, wait at least 1 minute for the engine control module (ECM) to
complete its shutdown before turning the battery disconnect switch to OFF.
Failure to follow this notice could cause damage to the machine or cause it to operate
improperly.
10. Turn the battery disconnect switch to OFF.
11. Lock right access door and engine hood.
12. Cover the exhaust opening to prevent contamination.