Aqua Matic Modular 450-1800
A. FEATURES PROGRAMMABLE BY OPERATOR
The following is an explanation of features that are
programmable by the operator. It is required that each
feature be set properly in order to gain maximum
performance of the System.
Only preinstalled features will be displayed on this screen.
1.
MANUAL MODE
Enable user to control the Booster Pump, HP
Pump, Diversion Valve and Pressure.
a) BOOSTER PUMP
Manually start and stop the Booster Pump.
b) HIGH PRESSURE PUMP
Manually start and stop the HP Pump.
c) DIVERSION VALVE SET POINT
Manually energize the 3-Way Product Water
Diversion Valve at a specific product water
quality, in PPM (Parts Per Million). The factory
setting is 800 PPM TDS (eight hundred Parts
Per Million Total Dissolved Solids expressed
as NaCl [sodium chloride - salt]).
Page 6-2
d) PRESSURE
Manually control the system pressure by
increasing or decreasing the setpoint of the
back pressure regulator.
2.
DISPLAY
Changes the color contrast of the touch screen for
better viewing.
3.
ACCEPTED SALINITY LEVEL
Changes the accepted salinity level by adjusting
the PPM level.
4.
BACK WASH TIME
Changes the interval for automatic back washing
by adjusting the number of days.
5.
LANGUAGE
Changes the current language used on the
controller by selecting new language option.
6.
UNIT
Toggles the measurement standards between U.S.
Standards and Metric Standards
Pressure: U.S. Standard = PSI (Pounds Per square
Inch); Metric Standard = kPa (kilo Pasquel)
Flow: U.S. Standard = GPM (Gallons Per Minute)
or GPH (Gallons Per Hour); Metric Standard = LPM
(Liters Per Minute) or LPH (Liters Per Hour).
6.4

CHECK SYSTEM MANUALLY

Refer to the P&ID in Section 3.
1.
Ensure that the manual By-Pass lever on the
3-Way Product Water Diversion Valve is positioned
outward (away from the coil body).
2.
Open any auxiliary valve within the incoming Feed
Line, Outgoing Brine Discharge Line, and Outgoing
Product Water Line.
WARNING: If any auxiliary valve is
installed in these lines, it will damage the
System if left closed during starting and/
or operation of the system. The resulting
damage is the liability of the operator.
3.
Position Rinse Clean Inlet Valve to normal
operation towards the Sea Restrainer.
4.
Position Rinse Clean Outlet Valve to normal
operation towards the Thru Hull Discharge Fitting.