Sea Recovery SRC Aqua Matic 450-1 Owner's Manual page 70

Reverse osmosis desalination system
Hide thumbs Also See for SRC Aqua Matic 450-1:
Table of Contents

Advertisement

Electrical Motor Wiring-Single Phase
1-BLU
VOLTAGE
2-WHT
220 - 230 VAC
3-ORG
110 - 115 VAC
4-YEL
J-BRN
NOTES
J-BRN
1. CONNECTIONS ARE SHOWN FOR CCW ROTATION FACING
END OPPOSITE SHAFT EXTENSION (STD). FOR CW
ROTATION, INTERCHANGE 5 AND 8 INTERNALLY.
2. OPTIONAL THERMOSTAT IS PROVIDED WHEN SPECIFIED.
3. MULTIPLE CAPACITORS ARE CONNECTED IN PARALLEL
UNLESS OTHERWISE SPECIFIED.
4. LEAD COLORS ARE OPTIONAL. LEADS MUST ALWAYS BE
NUMBERED AS SHOWN.
Sea Recovery
BOOSTER PUMP
ELECTRIC MOTOR
WINDINGS DIAGRAM CD0093
SINGLE PHASE
50/60 Hz
110-115 VAC // 220 - 230 VAC
RPM @ 50 Hz 2850 - @ 60 Hz 3450
1-BLU
VOLTAGE
2-WHT
220 - 230 VAC
3-ORG
110 - 115 VAC
4-YEL
J-BRN
J-BRN
NOTES
1. CONNECTIONS ARE SHOWN FOR CCW ROTATION FACING
END OPPOSITE SHAFT EXTENSION (STD). FOR CW
ROTATION, INTERCHANGE 5 AND 8 INTERNALLY.
2. OPTIONAL THERMOSTAT IS PROVIDED WHEN SPECIFIED.
3. MULTIPLE CAPACITORS ARE CONNECTED IN PARALLEL
UNLESS OTHERWISE SPECIFIED.
4. LEAD COLORS ARE OPTIONAL. LEADS MUST ALWAYS BE
NUMBERED AS SHOWN.
Sea Recovery
HIGH PRESSURE PUMP
ELECTRIC MOTOR
WINDINGS DIAGRAM CD0093
SINGLE PHASE
50/60 Hz
110-115 VAC // 220 - 230 VAC
RPM @ 50 Hz 2850 - @ 60 Hz 3450
Aqua Matic Modular 450-1800
LINE A
LINE B
JOIN
1
4
2, 3
1, 3
2, 4
--
LINE A
LINE B
JOIN
1
4
2, 3
1, 3
2, 4
--
Page 4-7

Advertisement

Table of Contents
loading