Daily Operation; Position Valves; Apply Power To The System; Start The System - Sea Recovery SRC Aqua Matic 450-1 Owner's Manual

Reverse osmosis desalination system
Hide thumbs Also See for SRC Aqua Matic 450-1:
Table of Contents

Advertisement

7.1

DAILY OPERATION

7.1.1

POSITION VALVES

VALVE
Inlet Sea Cock Valve
Rinse Clean Inlet Valve
Rinse Clean Outlet Valve
Multi Media Filter Valves
ANY auxiliary valve in the
Feed Line, Brine Discharge
Line, or Product Water Line
WARNING: If any auxiliary valve is
installed in these lines, it will damage the
System if left closed during starting and/
or operation of the system. The resulting
damage to the system is attributed to
improper installation, is the liability of the
operator, and is not covered by the Sea
Recovery warranty.
7.1.2

APPLY POWER TO THE SYSTEM

1.
Switch the Electrical Power Source, boat or home's
circuit breaker to the system "ON".
All Operating Screens WILL NOT include the
Automatic Fresh Water Flush components if the
Fresh Water Flush Option is not installed and the
control logic has been informed that the Fresh
Water Flush Option is not installed.
2.
After the control logic has initiated itself, the
default screen will appear indicating that the
System is ready to Start
7.1.3

START THE SYSTEM

A. AUTOMATIC MODE
The Automatic Mode is recommended for users & owners.
1.
From the default screen, touch the Start button.
2.
After the System has started, although the system
is producing "Product Water", the Product Water
may not be "Potable" for up to 30 minutes. The
POSITION
FULL OPEN
FROM SEA STRAINER TO
FRESH WATER FLUSH VALVE
FROM BRINE DISCHARGE
OF SYSTEM TO THRU HULL
DISCHARGE FITTING
NORMAL OPERATION
FULL OPEN
Aqua Matic Modular 450-1800
salinity of the Product Water diminishes gradually,
until it reaches the preset setting. When the
Product Water is Potable, the Ultra Violet Sterilizer
energizes. The Potable Water is then diverted by
the 3-way Product Water Diversion Valve to the
"Potable" (good water) position and into the Post
Filtration components onward to the Storage Tank.
All System readings, pressures, flows, and salinity
will be displayed on the Touch Screen.
3.
If any abnormality develops, touch the STOP button
and correct the problem.
4.
During operation, check for:
a) A constant feed water flow.
b) A consistent system pressure.
c) Leaks in the system.
d) Abnormal noises or other occurrences.
5.
Proceed to Log System Readings.
B. MANUAL MODE
The Manual Mode is intended for Sea Recovery
technicians for setup and configuration purposes.
NOTE: The Remote Touch Screen will be
blocked during operation in the Manual
Mode.
CAUTION: When the System is operated
in the MANUAL Mode Safety features will
still be controlled by the System Logic,
however AUTOMATED features will not
be controlled by the System Logic and
must be controlled by the operator.
1.
From the default screen, touch the SETUP tab.
2.
On the next screen, touch the Acceptable Salinity
Level button.
3.
On the Salinity Level screen, adjust to desired level
(188 to 370 PPM) then touch the SETUP button.
4.
On the next screen, touch the Manual Mode button.
5.
On the next screen, touch the Booster Pump
START button then wait 5 seconds for booster
pump to stabilize.
6.
Touch the HP Pump START button.
7.
Slowly increase the High Pressure level meter until
the System product flow rate if reached.
PRODUCT SALINITY (RED) simply means that the
Page 7-3