Sea Recovery SRC Aqua Matic 450-1 Owner's Manual page 83

Reverse osmosis desalination system
Hide thumbs Also See for SRC Aqua Matic 450-1:
Table of Contents

Advertisement

Aqua Matic Modular 450-1800
However, the Oil/Water Separator is
plumbed opposite of (backwards from) the
Commercial Prefilter. The standard filter
housings have raised arrows and lettering
molded indicating correct flow for the
Commercial Prefilter. These markings are
INCORRECT for the Oil/Water Separator.
The OIl/Water Separator's correct water
flow enters the center core of the filter
element and migrates to the outer surface
of the filter element.
15.
Pressure Differential Transducer.
The optional Pressure Differential Transducer
threads into the center port of the Low Pressure
Transducer Manifold.
CAUTION: Take care to NOT cross the
fine female threads in the manifold.
Thread in clockwise finger tight. Using a wrench
tighten an additional 45 degrees.
DO NOT OVER TIGHTEN.OVER TIGHTENING WILL
STRIP THE MANIFOLD FEMALE THREADS.
Using the supplied 1/4 in. (6.35 mm) O.D.
tubing connect the center Pressure Differential
Transducer Tube Fitting to the T-Connector
Pressure Pick-Up or to the Pressure Pick Up port of
the respective Prefiltration component. Refer to the
various Piping and Interconnect Diagrams Illustrated
in this Section 3.
16.
The HP Pump is mounted to a flat horizontal
surface using the 4 supplied 5/16-18x3/4 SS
Hex bolts, nuts and washer. The HP Pump
is mounted in an accessible location to allow
access for maintenance.
Set the HP Pump in place onto a flat surface and
mark the mounting holes.
Move the HP Pump out of the way and drill the
appropriate hole depending on which hardware
will be used. Place the HP Pump over the drilled
holes and attach the rubber isolation grommet
under the plate at each of the 4 mounting holes.
17.
RO Membrane Presure Vessels must be mounted
on a flat or vertical surface close to the HP
Pump. If possible allow 27-47 in. (68.6-119.4
cm) clearance at the ends for RO Membrane
maintenance.
The Pressure Vessel assembly can be removed
entirely from surface for maintenance.
Page 5-4
18.
UV Sterilizer Installation. The Ultra Violet Sterilizer
should be mounted on a flat horizontal or vertical
wall. Refer to Section 5.8 for installation details.
19.
The Fresh Water Flush Carbon Filter, with attached
Fresh Water Flush 2-Way Solenoid Valve and Fresh
Water Flush Check Valve is mounted to a flat
vertical surface in an accessible location for filter
element changing. Choose a location between
the Automatic Fresh Water Flush Check Valve and
a pressurized line from the boat's fresh water
pressure system.
CAUTION: In order to provide the
required flow of water to the Aqua Matic
System during the Fresh Water Flush
cycle, the Boat or Home's fresh water
pressure system must deliver minimum
1 U.S. Gallons (3.8 Liters) Per Minute at
minimum 25 PSI and maximum 60 PSI
( minimum 172 kPa and maximum 414 kPa ).
TUBING AND HOSE PRECAUTIONS
TUBE FITTING CONNECTIONS ASSEMBLY
a.
Cut tube end square and clean.
b.
Loosen nut on fitting three turns.
c.
Insert tube into fitting until it bottoms.
d.
Loosen nut completely and remove tube with
attached parts from body.
e.
Check to ensure that the O-Ring is seated
onto the tube under the spacer (and not
pinched into the body).
f.
Insert tube with attached parts into the body and
tighten nut finger tight.
CAUTION (Refer to fig. 5c, pg 5-5)
allow slack in all tube and hose lines.
Never cause the tube or hose to
immediately bend from the fitting. Allow
the line to enter or leave from the fitting
in a straight manner for several inches
to ensure proper connection, to relieve
stress to the fitting and tube or hose,
and to allow ease of detachment and
reattachment during maintenance or repair.
Always
: