Sea Recovery SRC Aqua Matic 450-1 Owner's Manual page 75

Reverse osmosis desalination system
Hide thumbs Also See for SRC Aqua Matic 450-1:
Table of Contents

Advertisement

Aqua Matic Modular 450-1800
Soft Start Wiring Diagram B596800006
Single Phase Wiring Connections:
FUSES (2A X 2)
WHT/BLK
WHT/RED
L1-BLK
L2 (N)RED
T1-BLK
T2-RED
T1-BLK
T2-WHT
If the Motor Soft Start is not already installed, follow these instructions to install it:
1. Disconnect the power source from the System.
2. Open the System or Controller Enclosure cover to access the Electrical Chassis.
3. Connect Motor Soft Start wiring as shown above.
Page 4-12
WHT/BLK
WHT/RED
L1-BLK
1
2
L2 (N)-RED
3
T1-BLK
4
5
T2 (N)-RED
6
T1-BLK
7
8
T2 (N)-RED
9
10
11
12
G-GRN
13
Note: Refer to the wiring diagram for details.
T1-BLK
Soft
T2-WHT
Start
G-GRN
T1-BLK
T1-B/W
M
T2-RED
T2-W/B
G-GRN
G-GRN
HP
Pump

Advertisement

Table of Contents
loading

Table of Contents