Provisioning
ESF-RAI to SF-RAI Overwrite (ROVR) Option. If the ESF-RAI to SF-RAI Overwrite (ROVR) option is
enabled, it allows a network ESF-RAI or ESF-RAI-CI pattern to be converted into a CPE SF-RAI or SF-RAI-CI
pattern.
If the ROVR option is disabled, it prevents conversion of a network ESF payload with an embedded RAI pattern.
Disabling the ROVR option preserves the integrity of the CPE payload as it was originally transmitted.
H2TU-R DS1 Frame Conversion (CONV) Option. Frame format conversion (see
applicable to the remote H2TU-R, but selectable by the H2TU-C or H2TU-R. This option enables the network to
be ESF, which is used to embed SPRM or NPRM into the datalink towards the network. During conversion, frame
bit errors are regenerated to ensure transparency.
The HDSL2 system attempts to find ESF or SF framing or determines that no framing exists. The DS1 framing is
then synchronized with the HDSL2 frame. If the framing is lost, the system generates an Out-of-Frame (OOF)
defect which results in Unavailable Seconds - Path (UAS-P). As a result, the system reverts to frame search mode.
This option has the following settings:
OFF: No frame conversion takes place. All framing issues are determined by the FRMG option settings of
AUTO and UNFR.
ACON: This is the automatic conversion setting. If the system detects ESF from the network and SF from the
CPE, it automatically converts the CPE SF to ESF towards the network as well as the network ESF to SF
towards the CPE.
Upon power-on-reset, after loopdown, or after changing the frame conversion option, the framing needs to
be re-established before a complete conversion takes place. If there is a failure condition (LOS, AIS, or LOF)
during steady state, the previous conversion state is maintained to ensure continuity when the system returns
from the failure condition.
If SF is received from the network, the H2TU-R forces an ESF towards the network for about 1.5 seconds.
This signals to the far-end PM-NIU at the network boundary that frame conversion is requested. If the far-end
PM-NIU is capable of conversion, it changes the framing to ESF. If not, then the H2TU-R reverts to SF and
does not apply any conversion.
If an ESF is received from the CPE, it is passed on to the network, and the network's inbound framing is
passed on to the CPE.
FCON: This is the forced conversion setting.
and FCON settings for the CONV option. The responses are identical, except in cases 3 and 4. In these cases,
the FCON reply is attempting to force the network (or the far-end PM-NIU) to send ESF. It also alerts the
CPE with an AIS alarm pattern while forcing the ESF to the network. Continuity is maintained as for ACON.
Table 10 on page 21
Case Number
NET Transmit
1
ESF
2
ESF
3
SF
4
SF
20
and
Table 11 on page 21
Table 9. Response to H2TU-R DS1 Frame Conversion Options
CPE Transmit
SF
ESF
ESF
SF
Table 9
lists the HiGain HDSL2 responses to both the ACON
list the ESF and SF frame formats, respectively.
ACON Option
NET > CPE
NET < CPE
ESF
SF
ESF ← SF
ESF
ESF
ESF ← ESF
SF
SF
ESF ← ESF
SF
SF
SF ← SF
June 6, 2003
LTPH-UM-1208-01
Table
9) is only
FCON Option
NET > CPE
NET < CPE
ESF
SF
ESF ← SF
ESF
ESF
ESF ← ESF
SF
AIS
ESF ← ESF
SF
AIS
ESF ← SF
H2TU-C-202 List 7G