Isdn1 Options Screen - ADC PG-PLUS PLL-722 Manual

Table of Contents

Advertisement

SCP-PLL722-010-04H
Alarm
Description
LOSW
COLU cannot receive data over the given HDSL loop. COLU and RT cannot synchronize and is out of
service.
ES-15
Number of HDSL ES has exceeded the user-configurable threshold to give advance warning that HDSL
Min.
performance is deteriorating. You can set this threshold from 0-15 ES over a 15-minute period, or disable
the alarm completely. 24 hour ES alarm threshold reached or exceeded.
ES-24 Hr. Number of HDSL ES has exceeded the user-configurable threshold to give advance warning that HDSL
performance is deteriorating. You can set this threshold from 0-255 ES over a 24-hour period, or disable
the alarm completely. 24 hour ES alarm threshold reached or exceeded.
MAR
HDSL noise margin of the loop has fallen below the user-configurable threshold. HDSL MAR reaches
or drops below the current threshold value.
PFO
COLU cannot power the RT due to an open circuit. An undercurrent condition as detected by the RT
exists for the given pair (<20 mA). A possible cause is that there is no RT at the other end of the circuit.
No user intervention is required.
PFS
COLU cannot power the RT due to a short circuit. An excessive current condition as detected by the
COLU exists for either pair (>50 mA). A PFS alarm indicates an overcurrent condition due to wire
shorting or an RT failure. The COLU automatically turns off power feeding to both loops in response to
a PFO or PFS condition on a single loop. No user intervention is required.

ISDN1 Options Screen

Provides access to configure the ISDN parameters. The values on the screen are the factory defaults. The Sealing
Current fields allows the current to be turned On or Off between the RT and the CPE. The EOC Mode field allows
the EOC processing type to be selected. The COLU and RT SES counts are the number of ISDN BE allowed
before SES count is incremented.
1
Select CONFIG at the menu bar and press
2
Scroll to the ISDN1 Options line and press
PLL-722 List 1
Table 10.
HDSL Alarms
to display the submenu.
ENTER
to view the screen:
ENTER
January 6, 2003
Configuration Submenu
Default
MN
MN
MN
MN
MN
MN
27