Alarms Submenu

ISDN History Screen

The ISDN History has two pages: the first relates to the COLU, and the second relates to the RT. The information
includes the alarm name, the provisional alarm type, the current status of the alarm, the number of times the alarm
was reported, the date and time of the first report alarm that of the last reported alarm. Here you see the results of
the alarms set at the Configuration
1
Select Alarms at the menu bar and press
2
Scroll to the ISDN History option and press
If there are no active alarms, the value
3
Select the
Display RLU ISDN Alarm History
4
Use the
Clear ISDN1 Alarm History
Clearing the alarm history clears the RT and the COLU alarm history, regardless of whether you clear it
from the COLU or the RT page of the history screen. If there is an active alarm, then the count is set to 1
and the value in the Last date and time field is set to the First date and time field. If an alarm is not active,
the count is reset to 0 and the time stamps for the first and last alarms are cleared.
5
Press
to move up a menu level, or
ESC
22
"ISDN Alarm Types Screen" on page
to display the submenu.
ENTER
to view the screen:
ENTER
displays in the
OK
field to move to the RT history page.
field at the bottom to clear the history information.
+