+ Inlet Compressed Air Temperature 100 °F (38 °C)
+ Inlet Compressed Air Pressure 100 psig (7 bar)
+ Maximum Ambient Air Temperature 100 °F (38 °C)
+ Inlet Compressed Air Relative Humidity 100% (Saturated)
SCFM is defined as the volume of free air in cubic feet per minute measured at 14.696 psia (1.013 bara) at 68 °F (20 °C)
temperature with 0% relative humidity (0 WVP).
3.2

Correction Factors

60 psig
correction
0.65
factor
How to determine adsorber capacity at operating conditions: How to select the adsorber for actual conditions:
ADJUSTED CAPACITY =
Standard Flow Rate x Correction Factor
Example:
Adsorber Model:
Standard Flow Rate:
Operating Conditions: 110 psig / 110 °F
ADJUSTED CAPACITY = 250 scfm x 1.12 - 280 scfm
CLEARPOINT V
7
70 psig
80 psig
0.74
0.83
CLEARPOINT® V 250
250 scfm
Series Activated Carbon Tower
®
Correction Factors
90 psig 100 psig 110 psig 120 psig 130 psig 140 psig 150 psig
0.91
1.00
1.12
ADJUSTED CAPACITY =
System Flow Rate ÷ Correction Factor
Example:
System Flow Rate: 300 scfm
Operating Conditions:
ADJUSTED CAPACITY = 300 scfm ÷ 1.20 = 250 scfm
Select Model:
(Rev. D)
1.20
1.25
1.16
130 psig
CLEARPOINT® V 250
1.29