8. TROUBLESHOOTING

BEHAVIOR
The Bed Frame does not
respond when Buttons are
pressed.
Parts of the Bed Frame re-
main in an elevated posi-
tion after a power failure.
26 //ADJUSTABLE BED FRAME - OWNER'S MANUAL
POSSIBLE CAUSE / SOLUTION
1. The Bed Frame is not connected properly. Check the power
connection
2. Time-out has been reached due to continuous operation. Do
not operate the Bed Frame for at least 6 minutes. This will re-
set the time-out.
3. Unplug the Power Converter. Wait until the LED goes out,
then plug it back in.
4. Replace the batteries in the Remote Control.
If power cannot be restored, an Emergency Lowering is required.
Proceed as follows:
1. Unplug the Power Converter from the power outlet.
2. Disconnect the Power Converter from the Cable Leading to
the Control Box.
3. Connect the Battery Strap to the Control Box Cable instead.
4. Connect two 9V batteries to the Battery Strap.
5. Use the Head DOWN/UP, Foot DOWN/UP or Sleeping Po-
sition Buttons to drive the Bed Frame to its lowest position.
Once Emergency Lowering is complete and power is restored,
you can reconnect the Power Converter. Then, perform a Ref-
erence Drive (see Chapter 5) and operate the Bed Frame as
normal.