ABB MagMaster Instruction Manual page 11

Electromagnetic
Hide thumbs Also See for MagMaster:
Table of Contents

Advertisement

Caution. (Remote versions)
• Remove any exposed black conductive layer from under coaxial screens.
• Make connections only as shown.
• Sleeve all bare wiring.
• Twist RED and YELLOW cores lightly together.
• Twist WHITE and GREY coaxial cables lightly together.
• Maintain Environmental Protection at all times.
• Conduit connections must provide cable entry sealing.
Information. (Remote versions)
• Refer to ENVIRONMENTAL PROTECTION (Appendix A).
• Internal appearance of Terminal Box may vary from that shown.
Standard Terminal Box
Note. If link is fitted, do NOT remove
Red
CD1
Yellow
CD2
SIG GND
Violet
DS1
Screen
SIG1
Blue
SIG2
Pink
Screen
DS2
Gray Coaxial
White Coaxial
Fig. 3.10 Sensor Terminal Box Connections (Remote version)
North American Wiring Practice
Red
Yellow
Black
White Coaxial
Screen
Cable
Blue
Black Coaxial
Pink
Cable
Screen
Fig. 3.11 Sensor Terminal Box Connections (North American Wiring Practice)
Ground Wire
ESCRN
(sleeved)
3 ELECTRICAL INSTALLATION...
Alternative Terminal Box
Note. If link is fitted, do NOT remove
Outer Screen
CD1
ESCRN
(sleeved)
CD2
SIG GND
DS1
SIG1
SIG2
DS2
7
––7 Screen
––6 Pink
––5 Blue
––4 Screen
––3 Violet
3
2
––2 Yellow
––1 Red
1
Ground Wire
(sleeved)
Green/Yellow (Ground)
Grey
coaxial
White
coaxial
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents