Belden HIRSCHMANN BAT-R User Manual
Hide thumbs Also See for HIRSCHMANN BAT-R:

Advertisement

Quick Links

User Guide - Hirschmann BAT (HiLCOS) Devices
with Paessler PRTG Network Monitor
Contents
Ensure SNMPv3 is enabled ..................................................................................................................... 2
Remove the admin user from SNMPv3 ................................................................................................. 2
Change the passwords ............................................................................................................................ 3
Copy the device template to PRTG ........................................................................................................ 4
Go to the Group Settings ......................................................................................................................... 5
Configure the SNMP Credentials ............................................................................................................ 5
Add a new device to a device group ....................................................................................................... 6
Configure the device name and address ............................................................................................... 6
Select the device template ...................................................................................................................... 7
Success ...................................................................................................................................................... 7
© Copyright 2022, Belden Inc.
2022-02-11
User Guide
1 of 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HIRSCHMANN BAT-R and is the answer not in the manual?

Questions and answers

Summary of Contents for Belden HIRSCHMANN BAT-R

  • Page 1 Configure the SNMP Credentials ......................5 Add a new device to a device group ....................... 6 Configure the device name and address ....................6 Select the device template ........................7 Success ..............................7 © Copyright 2022, Belden Inc. 2022-02-11 1 of 8...
  • Page 2 SNMPv3 is enabled by default, so it should already be enabled. Remove the admin user from SNMPv3 1. Remove the "admin" user: This user has permission to change settings over SNMPv3, which is not necessary © Copyright 2022, Belden Inc. 2 of 8...
  • Page 3 User Guide • Confirm on the next screen 2. Go to the "user" screen Change the passwords 1. Set a new password for authentication 2. Set a different password for privacy © Copyright 2022, Belden Inc. 3 of 8...
  • Page 4 User Guide Copy the device template to PRTG Copy the device template to this folder: Hirschmann BAT (HiLCOS).odt %PROGRAMFILES(X86)%\PRTG Network Monitor\devicetemplates © Copyright 2022, Belden Inc. 4 of 8...
  • Page 5 • User is "user", just like on the BAT configuration • "Password" is the "Password for auth." from the previous steps • "Encryption Key" is the "Password for priv." from the previous steps © Copyright 2022, Belden Inc. 5 of 8...
  • Page 6 User Guide Add a new device to a device group Configure the device name and address These are example values. © Copyright 2022, Belden Inc. 6 of 8...
  • Page 7 • This device has no "WLAN Module 2", so this sensor can be removed • By default the "Telnet" connection is disabled, so either remove the sensor or change it to expect this test to fail as a security check © Copyright 2022, Belden Inc. 7 of 8...
  • Page 8 User Guide © Copyright 2022, Belden Inc. 8 of 8...