Contents Safety instructions About this manual Description General description Device name and product code Device view Power supply 1.4.1 Supply voltage with the characteristic value W (24 V DC) 1.4.2 Supply voltage with the characteristic value P (Power supply only through PoE) Ethernet port 1.5.1 10/100/1000 Mbit/s PoE port 1.5.2 Pin assignments...
Page 4
First login (Password change) Obtain compliance for operation in the European Union Configuring the transmit power Monitoring the ambient air temperature Maintenance and service Disassembly Technical data 10.1 General technical data 10.2 Dimension drawings 10.3 Radio technology 10.4 Roaming 10.5 Receiving sensitivity, transmit power and data rate 10.5.1 IEEE 802.11b 10.5.2 IEEE 802.11g 10.5.3 IEEE 802.11a...
Safety instructions WARNING UNCONTROLLED MACHINE ACTIONS To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices individually. Before you start any machine which is controlled via data transmission, be sure to complete the configuration of all data transmission devices. Failure to follow this instruction can result in death, serious injury, or equipment damage.
Page 6
Installation site requirements Use the device only indoors. Restricted access location: The location is outside the operator access area. The location is accessible to the service personnel even when the device is switched on. Indoor operator access area: ...
Page 7
National and international safety regulations Verify that the electrical installation meets local or nationally applicable safety regulations. When installing antennas, observe the regulations of the country in which you are operating the WLAN device with regard to the general operating permission and the maximum emission levels.
Page 8
Requirements for connecting electrical wires Before connecting the electrical wires, always verify that the requirements listed are complied with. The following requirements apply without restrictions: The electrical wires are voltage-free. The cables used are permitted for the temperature range of the application case. ...
Page 9
Requirements for connecting the supply voltage The following requirements apply without restrictions: All of the following requirements are complied with: The supply voltage corresponds to the voltage specified on the type plate of the device. The power supply conforms to overvoltage category I or II. ...
Page 10
CE marking The labeled devices comply with the regulations contained in the following European directive(s): 2011/65/EU and 2015/863/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
Page 11
Notes for countries with the following country codes: AT BE BG CH CY CZ DE DK EE EL ES HR HU LV MT NL NO PL PT RO RS SE TR UK The RED compliance requires compliant operation of the device in the 5 GHz band channels.
Page 12
Notes for Germany (DE), Ireland (IE), and the United Kingdom (UK): DE IE Operation in the 5.8 GHz band at a radiated power (EIRP) >25 mW is subject to meeting the following conditions: Germany (DE) Frequency range: 5725 MHz to 5875 MHz Condition: The usage of this band is restricted to commercial public telecommunication services.
Page 13
Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information BAT867-F U.S. Contact Information Belden – St. Louis 1 N. Brentwood Blvd. 15th Floor St. Louis, Missouri 63105, United States Phone: 314.854.8000 This device complies with part 15 of the FCC rules.
Page 14
IC: 7849A-WLE600VX This equipment complies with FCC and IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. Install and operate this equipment with a minimum distance of 19.7 in (50 cm) (related to a 9 dBi antenna) between the radiation source and your body. The antenna used for this transmitter must not be co-located with any other transmitters within a host device, except in accordance with FCC multi-transmitter product procedures.
About this manual The “Installation” user manual contains a device description, safety instructions, a description of the display, and the other information that you need to install the device. Documentation mentioned in the “User Manual Installation” that is not supplied with your device as a printout can be found as PDF files for downloading on the Internet at: https://www.doc.hirschmann.com Installation BAT867-F...
Description General description The devices allow you to set up WLANs (Wireless Local Area Networks) in a local network. In contrast to a conventional network connection through copper cables and fiber optic cables, some of the communication is performed by means of a radio link. The devices allow you to install a new LAN or expand an existing LAN.
1 ... 8 Product BAT867-F IP65/67 housing 9 ... 10 Country approvals You can determine the current country approvals using the configurator (https:// catalog.belden.com) Example: Example: Singapore Slot 1 WLAN module Slot 2 Not assembled Slot 3 Not assembled...
Page 19
Item Characteristic Character Description istic value Configuration Accessory package Not present Device model Hirschmann standard Table 3: Device name and product code Installation BAT867-F Release 01 12/2019...
Device view Antenna connection 2 Antenna connection 1 LED display elements Functional earth screw Reset button behind a screwable IP65/67 protection cap Applies to device variants featuring supply voltage with characteristic value W (24 V DC): 5-pin, “A”-coded M12 socket 8-pin, “X”-coded M12 plug for 10/100/1000 Mbit/s PoE port Power supply 1.4.1...
Power supply via a 5-pin, “A”-coded M12 plug For the power supply of the device, a 5-pin, “A”-coded M12 plug is available. 1.4.2 Supply voltage with the characteristic value P (Power supply only through PoE) Power supply via an 8-pin, “X”-coded M12 socket for PoE ...
Connections for antennas The device has connections for external antennas. These connections are N sockets. The "Antenna Guide" document provides an overview of the antennas that can be used as well as the suitable antenna accessories. The manual is available for download on the Internet: https:// www.doc.hirschmann.com Display elements...
WLAN Activity Meaning Color green flashing DFS scanning or another scan procedure Display of signal strength in client or P2P flashing Device has detected at least one hardware error. Reset button The device has a reset button. The reset button is located behind a screwable IP65/67 protection cap.
Installation The devices have been developed for practical application in a harsh industrial environment. On delivery, the device is ready for operation. Perform the following steps to install and configure the device: Checking the package contents Installing and grounding the device ...
Verify that the device maintains the minimum clearance to meet the climatic conditions during operation: Top and bottom sides of device: 2 in (5 cm) Left and right device side: 0.79 in (2 cm) To protect the exposed uninstalled contacts of the components from dirt, connect the individual system components in a dry and clean working area.
Installing the antennas Install the antennas only indoors. The device has connections for external antennas. These connections are N sockets. On delivery, the connections are sealed with protection caps. Proceed as follows: Remove the protection caps from the connections to which you want to connect external antennas.
Supply voltage with the characteristic value W (24 V DC) Type and specification of the supply Pin assignment on the device voltage Rated voltage DC: 1 +24 V DC 24 V DC Voltage range DC incl. maximum 2 0 V DC tolerances: 3 0 V DC 18 V DC ...
Page 29
Further information: “10/100/1000 Mbit/s PoE port” on page 21 Installation BAT867-F Release 01 12/2019...
Making basic settings The IP parameters must be entered when the device is installed for the first time. The device provides the following options for configuring IP addresses: Entry via the HiDiscovery protocol in the applications HiDiscovery or Industrial HiVision ...
Type in your new password. Choose a password that contains at least 8 characters which includes upper-case characters, lower-case characters, numerical digits and special characters. Confirm your new password. For further information see: https://hirschmann-support.belden.com/en/kb/required-password-change- new-procedure-for-first-time-login Installation BAT867-F Release 01 12/2019...
Obtain compliance for operation in the European Union For operation in the European Union, the device must comply with the Radio Equipment Directive (RED) 2014/53/EU. The RED compliance requires compliant operation of the device in the 5 GHz band channels. Compliant operation of the device is achieved by an unchangeable determination of the country setting.
Page 33
Note: To check the country setting and correct it, type no. Then check the country setting with the following command: ls Setup/WLAN/ Country. To obtain RED compliance, type yes. This makes the country setting unchangeable. Subsequently, the device restarts. Graphical user interface ...
Page 34
To confirm your choice, click the “OK” button. In the LANconfig device overview, highlight the row containing the desired device. In the menu bar, select Device > RED compliance. Note: To check the country setting and correct it, click the “No” button. Then open the Configuration >...
Configuring the transmit power Note: The operator of a WLAN radio installation must adhere to the applicable transmission threshold values. Use the graphical user interface or the LANconfig software. You can download the LANconfig software as an ISO image from the Hirschmann product pages (www.hirschmann.com).
Page 36
Subtract the cable and installed overvoltage protector attenuation from the antenna gain. Enter the calculated value in the “Antenna gain” field. To save the value, click the “Send” button. Installation BAT867-F Release 01 12/2019...
Monitoring the ambient air temperature Operate the device below the specified maximum ambient air temperature exclusively. See “General technical data” on page 40. The ambient air temperature is the temperature of the air at a distance of 2 in (5 cm) from the device. It depends on the installation conditions of the device, for example the distance from other devices or other objects, and the output of neighboring devices.
Maintenance and service When designing this device, Hirschmann largely avoided using high-wear parts. The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally. Operate this device according to the specifications. ...
Disassembly WARNING ELECTRIC SHOCK Disconnect the grounding only after disconnecting all other cables. Failure to follow this instruction can result in death, serious injury, or equipment damage. Disconnect the data cables. Disable the supply voltage. Disconnect the power supply cable. ...
10 Technical data 10.1 General technical data Dimensions BAT867-F See “Dimension drawings” on page 41. W × H × D Weight approximately 31.75 oz (900 g) Supply voltage Rated voltage 24 V DC Voltage range incl. maximum 18 V DC ... 32 V DC tolerances Connection type 8-pin, “X”-coded M12 socket for PoE port or...
10.3 Radio technology Antenna connection 2 × N socket for WLAN module Range Depending on the antenna used, frequency range and data rate Encryption IEEE 802.11i/WPA2 with passphrase or IEEE 802.1x and hardware-accelerated AES Closed Network WEP 64 ...
10.5 Receiving sensitivity, transmit power and data rate The values of the WLAN module shown in the following tables are subject to a tolerance of ±2 dB. If you use only 1 antenna, the transmit power is reduced by 3 dB. The values are in no case to be perceived as a guaranteed property of the overall product.
EMC interference immunity EN 61000-4-3 Electromagnetic field 80 MHz ... 1000 MHz 10 V/m 1400 MHz ... 2700 MHz 10 V/m EN 61000-4-4 Fast transients (burst) DC power line ±2 kV Data line ±4 kV EN 61000-4-5 Voltage surges DC power line ±1 kV line/ground;...
11 Scope of delivery, order numbers and accessories Scope of delivery Number Article 1 × Device 1 × Safety and general information sheet 1 × EU Declaration of Conformity 1 × Protection cap (M12, plastic) for supply voltage connection premounted 2 ×...
Page 50
The "Antenna Guide" document provides an overview of the antennas that can be used as well as the suitable antenna accessories. The manual is available for download on the Internet: https:// www.doc.hirschmann.com Designation Order number BAT-ANT-N-3AGN-IP67 for N socket 942-110-001 (10 pieces) 50 Ω...
12 Underlying technical standards Name EN 50121-4 Railway applications – EMC – Emission and immunity of the signaling and telecommunications apparatus (Rail Trackside) EN 55032 Electromagnetic compatibility of multimedia equipment – Emission Requirements EN 60529 Degrees of protection provided by housing – IP-Code EN 61000-6-1 Electromagnetic compatibility (EMC) –...
A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https:// hirschmann-support.belden.com. This site also includes a free of charge knowledge base and a software download section. Hirschmann Competence Center The Hirschmann Competence Center is ahead of its competitors on three counts with its complete range of innovative services: ...
Need help?
Do you have a question about the Hirschmann BAT867-F and is the answer not in the manual?