Page 3
Limitations of use can apply in respect of operating freuency, transmitter power and/or channel spacing. Declaration of Conformity Hereby, R.V.R. Elettronica SpA, declares that this FM transmitter is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
VJ2000 7. Maintenance Procedure 7.1 Safety Procedures FIRST LEVEL OF MAINTENANCE 7.2 Routine Maintenance SECOND LEVEL OF MAINTENANCE 7.3 Replacements of the Components N.B. TO RE-ASSEMBLE THE UNIT, SIMPLY REVERSE THE SEQUENCE OF OPERATIONS. N.B. THE FOLLOWING PROCEDURE SHOULD ONLY BE CARRIED OUT BY QUALIFIED PERSONNEL USING THE CORRECT TOOLS AND EQUIPMENT. UNQUALIFIED OR...
Page 36
VJ2000 7.4 Replacement of the Tube 7.5 Changing the Rear Grill Air Filter 7.6 Changing the Front Grill Air Filter...
VJ2000 8. Calibration Procedure N.B. THE FOLLOWING PROCEDURE SHOULD ONLY BE CARRIED OUT BY QUALIFIED PERSONNEL USING THE CORRECT TOOLS AND EQUIPMENT. UNQUALIFIED OR INEXPERIENCED PERSONNEL NOT USING THE CORRECT TOOLS AND EQUIPMENT CAN EASILY CAUSE DAMAGE TO THE UNIT WHICH WILL IMMEDIATELY INVALIDATE THE GUARANTEE.
Page 38
VJ2000 8.2 Calibration of the Protection Board N.B. Several attempts may be necessary. At least 60 seconds should be allowed inbetween attempts to allow an automatic reset.
Page 40
VJ2000 8.3 Calibration of the Grid Current Meter (IG) 8.4 Calibration of Anode Current Measurement (IA) 8.5 Calibration of Heater Voltage Measurement (HEATER)
Page 41
VJ2000 8.6 Calibration of Plate Voltage Measurement (PLATE) WARNING : 8.7 Calibration of the PWR Meter (FWD-PWR LECTURE) N.B. The trimmer R2 connected in series with the meter allows small adjustments after the calibration of PWR, REF and FWD, and is normally in a central position. SETUP 7...
Page 42
VJ2000 8.8 Calibration of the PWR Meter (REF-PWR LECTURE)
Need help?
Do you have a question about the VJ2000 and is the answer not in the manual?
Questions and answers