Graco G3 Series Instructions Manual page 48

Hide thumbs Also See for G3 Series:
Table of Contents

Advertisement

Alarms
Cycle /
Pressure
Warning
HH
MM : SS
Cycle /
Pressure
HH
Fault
MM : SS
48
MM
SS
##
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
MM
SS
##
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
System is over pressur-
ized or a lubrication cycle
was not completed in the
user-defined amount of
time.
Unit will continue to oper-
ate for the number of lubri-
cation cycles set by the
warning retry parameter
(see Advanced Program-
ming, page 40).
If the warning condition
clears itself on the next
automatic lubrication cycle,
the warning is cleared and
the unit continues normal
operation.
In pressure mode indi-
cates that unit is over pres-
surized or a lubrication
cycle was not completed in
the user-defined amount of
time.
In cycle mode indicates
that a cycle was not com-
pleted in the user-defined
amount of time.
LED corresponding to the
affected sensor input
blinks.
Could be more than one
sensor alarm at the same
time.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press the
RESET but-
ton to clear
warning.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press the
RESET but-
ton to clear
warning.