2. Press the ENTER button to set the num-
ber. The cursor automatically moves to
the next number field.
3. Repeat steps 1 and 2 for each PIN Code prompt
field.
If the PIN Code you entered is correct, the first editable
character on the display will flash.
Selecting Advanced Setup Options
1. Press the UP or DOWN
ARROW button to move up or
down through Advanced
Options A1 - A5.
2. Press the ENTER button to set the
selection.
A1 - Setting Up PIN Code
A PIN Code can be programmed into the G3 to protect
the settings from inadvertently being changed by unau-
thorized users.
The LED next to the LOCK ICON on the dis-
play lights, indicating you have entered the
PIN Mode.
1. The cursor automatically is
positioned to entered the first
character of the PIN Code.
Use the UP and DOWN
ARROW buttons to move up
and down through the numbers 0-9 until the first
number in the PIN code is displayed in the field.
2. Press the ENTER button to set the num-
ber. The cursor automatically moves to
the next number field.
3. Repeat steps 1 and 2 for each PIN Code prompt
field.
4. The word OFF appears in the
display. Press the UP or
DOWN ARROW button to
change this to ON.
5. Press the ENTER button to set the PIN
Code and enter Advanced Setup.
3A0414B
A2 - Low Level Alarm Time
Pump ON mode only.
Programs the amount of time in MM: SS (minutes and
seconds) the pump can run between a Low Level Warn-
ing and a Low Level Fault to help protect unit from run-
ning dry.
The maximum recommended length of time is 3:00 min-
utes.
Fault, and Low Level LED illuminate. (Max Model Dis-
play shown in illustration below).
F
. 13
IG
NOTE: When programming a time of less than 10 min-
utes you must program a leading zero in the first num-
ber field and press the ENTER button to save the zero
selection.
1. To set the time use the UP or
DOWN ARROW button to
scroll through numerals 0 to 9
until the desired number
appears in the first MM (min-
utes) field.
2. Press the ENTER button to lock in the
selection. The next MM number field to
the right flashes indicating it is ready for
programming.
Advanced Programming