1. After you set the Machine Count Backup Time field
and press the ENTER button, the G3 automatically
switches to the Prelube Delay setup.
Notice the LED next to the prelube
icon on the G3 display lights indicat-
ing you are now in the Prelube setup
mode.
2. OFF displays. If you
want the prelube
cycle to begin imme-
diately, leave this set
to OFF.
3. Press the ENTER button to set the
selection.
4. If you want to set a
prelube delay time,
press the DOWN
ARROW button to
change OFF to ON
on the display.
5. Prelube Delay is set
in MM:SS (minutes and sec-
onds). To set the time use the
UP or DOWN ARROW button
to scroll through numerals 0
to 5 until the desired number
appears in the first MM (minutes) field.
The maximum length of time Prelube Delay can be
set to is 59:59 (59 minutes:59 seconds).
6. Press the ENTER button to lock in the
selection. The next MM number field to
the right flashes indicating it is ready for
programming.
7. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second MM number
field.
8. Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under SS; indicating it is
ready to program the seconds fields.
3A0414B
9. Repeat steps 5 - 8 to set the SS (seconds) fields.
10. After pressing the ENTER button to set
the last SS field the G3 automatically
switches to the RUN MODE.