Graco G3 Series Instructions Manual page 45

Hide thumbs Also See for G3 Series:
Table of Contents

Advertisement

Cycle (C1) / Pressure (P1) Control
The display alternates between cycles (C1, C2, C3) or
active sensor (P1, P2, P3) and time.
In Cycle Mode the lubrication period is ended by
either:
Cycle Control
A set number of triggered counts in a cycle
based system (C1) (typically a proximity switch
connected to a divider valve) (F
SS
HH
MM
ON
MM : SS
C
1
P
C
C
2
P
C
P
3
P
F
. 18
IG
OR
Pressure Control
A single triggered count in a pressure based
system (P1) (typically a pressure switch on the
end of a line of injectors) (F
3A0414B
. 18).
IG
##
!
OFF
HH : MM
1 2 3
. 19).
IG
HH
MM
SS
ON
MM : SS
C
1
P
C
C
2
P
C
P
3
P
F
. 19
IG
Machine Count
A numeric count down of either machine counts or
Time appears on display (F
HH
MM
SS
ON
MM : SS
C
1
P
C
C
2
P
C
P
3
P
F
. 20
IG
Run Mode
##
!
OFF
HH : MM
1 2 3
. 20).
IG
##
!
OFF
HH : MM
1 2 3
45