A-4 Alarm Retry (Max Model Only)
Programs the number of times G3 will automatically
retry running a lubrication cycle after a cycle or pressure
alarm activates. The default setting is 0. For assistance
determining a reasonable number of Alarm Retries to
program for your application, contact Graco Customer
Service or your local Graco distributor.
1, 2, and 3 and Fault LED's illuminate.
F
. 14
IG
To set the Alarm Retry:
1. The default value
0000 appears in the
display.
2. Press the UP or DOWN
ARROW button to move up or
down through number 0-9.
3. When the correct number displays,
press the ENTER button to set the num-
ber.
4. Repeat 2 - 3 to set the remaining fields.
Press the ENTER button to exit Advanced
Programming.
3A0414B
A-5 Active Alarm (Max Model Only)
Changes the alarm output behavior. Uses output to
determine if a fault has occurred.
Fault and ON LED's illuminate.
F
. 15
IG
1. The default OFF dis-
plays.
2. Press the DOWN ARROW button to
change OFF to ON on the display to
activate alarm condition.
3. Press the ENTER button to exit
Advanced Programming.
Advanced Programming
43