Advanced Programming
3. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second MM number
field.
4. Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under SS; indicating it is
ready to program the seconds fields.
5. Repeat steps 1 - 4 to set the SS (seconds) fields.
6. After pressing the ENTER button to set
the last SS field, all the programmed ON
Time information is saved.
Unit exits Advanced Programming.
A-3 Vent Valve Time - (Max Model Only)
The Vent Valve Time is the amount of time the vent
valve stays open after a cycle is completed.
The recommended Vent Valve Time is 5 minutes.
To bypass the Vent Valve Time enter a value of 00:00.
Vent Valve time must be less than the programmed OFF
time (page 32). If it is not set to a value less than the
programmed OFF time, the G3 will automatically adjust
the time to a value 2 seconds less than the set OFF
time.
To set Vent Valve Time:
NOTE:
The LED next to the clock in the OFF
field lights and P1, P2, and P3, indi-
cating the Vent Valve Time is being
programmed.
Time is set as minutes and seconds (MM:SS) only.
42
The small flashing
LED under the MM
indicates you are
setting Minutes.
The first field (left
side of display) blinks
indicating the device
is ready for you to
begin programming.
When programming a time of less then 10 minutes
you must program a leading zero in the first number
field and press the ENTER button to save the zero
selection.
1. To set the Time use the UP or
DOWN ARROW button to
scroll through numerals 0 to 5
until the desired number
appears in the first minute
field.
2. Press the ENTER button to lock in the
selection. The next minute field to the
right flashes indicating it is ready for
programming.
3. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second minute field.
4. Press the ENTER button to lock in the
selection.
5. The next number field
to the right flashes
and the LED lights
under SS; indicating
it is ready to program
the Seconds fields.
6. Repeat steps 1 - 4 to set the MM (seconds) fields.
7. After pressing the ENTER button to set
the last seconds field, all the pro-
grammed Time information is saved.
Unit exits Advanced Programming.
3A0414B