7 Servicing/Maintenance
Fig. 29: Lubricating nipple
Part No.
Description
970.06
Sign with the following text:
Schmierung Waelzlager
Lubrication antifriction bearing
903.46
Lubricant filler opening
411.46
636.02
Always apply a liquid sealant (e.g. Hylomar SQ32M) to sealing
FD
surfaces marked with this symbol.
ü The pump set has been positioned on a level surface.
ü The pump set is secured against tipping over.
1. Remove screw plug 903.46 and joint ring 411.46.
2. Connect the pump set to the power supply. (ð Section 5.4.2, Page 43)
CAUTION
Pump set running dry
Increased vibrations!
Damage to mechanical seals and bearings!
▷ Never operate the pump set for more than 60 seconds without the fluid
handled.
3. Start up the pump set.
4. Fill in grease via lubricating nipple 636.02.
5. Disconnect the pump set from the power supply again and make sure it cannot
be started up unintentionally.
6. Apply a liquid sealant to screw plug 903.46 and screw it back in together with
new joint ring 411.46.

7.5 Checking the connection of motor/power supply

Check the electric cables after reassembly. (ð Section 7.2.1, Page 53)
Amacan K
970.06
903.46
FD
411.46
636.02
63 of 126