Checking The Connection Of Motor/Power Supply - KSB Amarex KRT Installation & Operating Manual

Submersible motor pump sizes dn 40 to dn 300
Table of Contents

Advertisement

7 Servicing/Maintenance
Observe the following values for leak testing:
▪ Test medium: compressed air
▪ Test pressure: 0.8 bar maximum
▪ Test duration: 2 minutes
Fig. 36: Screwing in the testing device
1. Unscrew and remove the screw plug and joint ring of the lubricant reservoir.
2. Screw the testing device tightly into the lubricant filler opening.
3. Carry out the leak test with the values specified above.
The pressure must not drop during the test period.
If the pressure does drop, check the seals and screwed connections.
Repeat the leak test.
4. If the leak test has been successful, fill in the lubricant.

7.5.5 Checking the connection of motor/power supply

Check the power cables after reassembly. (ð Section 7.2.2, Page 57)
7.6 Tightening torques
Table 27: Tightening torques [Nm] depending on thread, material and property class
Thread
A4-50
210
[Nm]
M 5
-
M 6
-
M8
-
M10
-
M12
-
M14
-
M16
-
M20
-
M24
230
M30
460
M42
1300
M48
1950
Amarex KRT
P
Tightening torque
Material
A4-70
Property class Rp 0.2 
N
/
250
450
[Nm]
[Nm]
-
4
-
7
-
17
-
35
-
60
-
90
-
150
-
290
278
-
-
-
-
-
-
-
1.4462
8.8
mm²
450
640
[Nm]
[Nm]
4
6
7
10
17
25
35
50
60
85
90
130
150
210
290
410
500
700
1000
1400
2750
3900
4200
6000