Installing A Doubler Or Remote Unit - ADC HiGain HRE-450 List 4A User Manual

Remote enclosure
Hide thumbs Also See for HiGain HRE-450 List 4A:
Table of Contents

Advertisement

150-450-141-02, Issue 2
I
NSTALLING
To install a doubler or remote unit in the HRE-450 List 4A:
1
Loosen the wingnuts on the strap, then pull the strap away from the mounting plate.
2
Slide the doubler or remote unit into the slot until firmly seated.
If Vdc is present, the doubler or remote unit begins an initial power-on cycle within 30 seconds.
Strap
Wingnuts
Figure 9. Installing a Remote or Doubler Unit in an HRE-450 List 4A
3
Verify the following:
If the installed unit is a doubler, and the remote unit is not yet installed in the system, the doubler
completes its initial power-on cycle and two HDSL IN LEDs light green.
If the installed unit is a doubler, and the remote unit is installed in the system, the doubler completes its
initial power-on cycle and the two HDSL IN and two HDSL OUT LEDs light green.
If the installed unit is a remote unit, the unit completes its initial power-on cycle and both front-panel
HDSL LEDs light green.
HRE-450 List 4A
A D
OUBLER
August 18, 1998

Installing A Doubler Or Remote Unit

O
R
R
EMOTE
Remote or
doubler unit
U
NIT
11