150-450-141-02, Issue 2
Figure 7. Preparing the Wire Pair for Insertion into the Quiet-Front Connector Modules
Do not strip the drop-wire pair insulation.
9
Use a Type 216C (
Do not rotate the QFCM lug more than
10
Insert the first pair's Tip wire into the left Wire-Entry hole on the left QFCM, until the wire touches the ends
of the transparent plastic caps.
11
Insert the first pair's Ring wire into the right Wire-Entry hole on the left QFCM, until the wires touch the ends
of the transparent plastic caps. (See
12
While holding the Tip and Ring wires in place with your fingers, use a Type 216C (
each QFCM lug
1
HRE-450 List 4A
7
/
in.) wrench to rotate each QFCM lug
16
Wire-entry hole
Wire-entry hole
Figure 8. Locating the QFCM Lug
Figure 6 on page 9
/
turn clockwise.
4
August 18, 1998
50.8 mm
(2")
1
/
turn counterclockwise to open the connectors.
4
1
/
turn, or it may fall off the QFCM.
4
QFCM lug
Wire-entry hole
for a complete wiring diagram).