Installation
Do not rotate the QFCM lug more than
13
Using your fingers (do not use a pliers or wrench), tighten the cable lock nut. If necessary, use groove-joint
pliers to hold each cable rifting center locknut while tightening each compression nut with your fingers.
14
Repeat
Step 10
through
15
Use cable ties to dress the wires that enter the enclosure box and connect to the QFCM terminals, per local
practice.
16
Position and secure the ground wire along the installation surface and connect it to a nearby ground, per local
practice.
10
1
/
4
Step 13
using the second wire pair and the right QFCM.
August 18, 1998
turn.