Installation
3
1
Using a
/
in. can wrench, or an adjustable wrench, loosen the screw on the HRE-450 List 4A cover, then
16
remove the cover.
2
Make sure that each of the two compression connector nuts is secure. If a nut is not secure, tighten it using
your fingers.
Compression connector nuts
Ground wire access
3
Place the HRE-450 List 4A in the selected installation location, then mark the mounting screw hole locations
on the installation surface, using the mounting screw guides (see
6
ADC
HRE 450
TELEPHONE COMPANY PROPERTY
Cover screw
Figure 3. Locating the HRE-450 List 4A Cover Screw
Figure 4. Bottom of the HRE-450 List 4A
August 18, 1998
Mounting bracket
Cable stub
Figure
5).