No spark at pilot burner.
Inappropriate inlet pressure
Air seal issue around pilot.
Clogged pilot gas line.
Valve is defective
Receiver is defective
Pilot is lit, and control continues to spark. Valve shuts after 10-30 seconds.
Over tightened thermocouple interrupter
Thermocouple is defective
Receiver is defective
Pilot is lit and sparking stops. Valve shuts after 3-60 seconds. Valve does not operate manually.
Not enough voltage generated from the thermocouple
or too much resistance in the circuit.
Low inlet pressure.
Thermocouple is defective
Valve is defective
3 short beeps while the motor turns
Receiver batteries are low
Low inlet pressure
Main gas burner line is crimped
Valve is defective
Check spark gap; Check for spark in location along cable.
Check spark on the receiver by disconnecting the spark
cable from the receiver.
Inspect and correct as needed.
stem-lighter.
Reset receiver and attempt to re-ignite.
Replace valve
Replace receiver and reprogram code.
Contact customer service or gas technician
Replace thermocouple
Replace receiver
Use a digital multimeter set in the mV range and measure
the voltage by connecting the test leads to the spade
connector. Spade connector is located on the outer
voltage must be at least 5 mV. The manufacturer must
specify the drop time for the application. The drop time can
be measured after the thermocouple is heated.
necessary.
Replace thermocouple
Replace valve
Contact customer service or gas technician
handset.
Contact customer service or gas technician
Contact customer service or gas technician
Replace valve