Chapter 2 — Control and Adjustment
IPL
Controlling the LTS
The label taken sensor works when the printer is in self-strip mode. The
self-strip mode can be enabled or disabled using the following IPL com-
mands:
enter print/confi guration mode
<STX>R<ETX>
n = 1 enables self-strip
<STX>SI>tn<ETX>
n = 0 disables self-strip
Adjusting the LTS
The sensitivity of the Label Taken Sensor (LTS) may need to be adjusted
according to the ambient light conditions and the refl ective character-
istics of the back side of the media. The sensitivity can be adjusted in
the Setup Mode. There are no straps or potentiometers for adjusting the
LTS.
Refer to the User's Guide, chapters "Setting Up the Printer" and "Setup
Mode" for instructions how to adjust the LTS.
• In the Setup Mode, step to the Confi guration Part.
• Select Confi guration/LTS Calibration.
• Follow the instructions shown in the display.