DCFT-MCD ERROR CODE MATRIX
Component
Error
Designation
Code
Description
Main Platen
10
Probe shorted
Main Platen
11
Redundant heater
Main Platen
12
switchover mode
Redundant heater
Main Platen
13
switchover error
Front Club
20
Probe shorted
Platen
Front Club
21
Platen
Front Club
drifted too low for
22
Platen
too long. 25°F
below setpoint for
Rear Club Platen
30
Probe shorted
Rear Club Platen
31
drifted too low for
Rear Club Platen
32
too long. 25°F
below setpoint for
Motor
40
Motor tach error
Motor
41
Motor load error
527-504revM_EN
Problem
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
Shut off power to the toaster, wait 30 seconds and turn
Probe Open
back on. If the error code is still present or reappears
within 24 hours, call for service.
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
Shut off power to the toaster, wait 30 seconds and turn
Probe open
back on. If the error code is still present or reappears
within 24 hours, call for service.
Heater
temperature
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
5 minutes.
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
Shut off power to the toaster, wait 30 seconds and turn
Probe open
back on. If the error code is still present or reappears
within 24 hours, call for service.
Heater
temperature
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
5 minutes.
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.
Shut off power to the toaster, wait 30 seconds and turn
back on. If the error code is still present or reappears
within 24 hours, call for service.

Fault Codes

Action to Take
65
Vertical Toaster
DCFT-MCD Series
Error Message to Display
Dual Display Mode
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Main Probe Shorted
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Main Probe Open
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Heater switchover
mode
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Heater switchover
error
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Front Club
Probe shorted
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Front Club
Probe open
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Front Club
Power ON
Low temp error
if problem exist
Power OFF
Wait 30 seconds
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Rear Club
Probe shorted
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Rear Club
Probe open
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Rear Club
Power ON
Low temp error
if problem exist
Power OFF
Wait 30 seconds
Call for service
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Motor speed error
Power ON
if problem exist
Power OFF
Call for service
Wait 30 seconds
Initial screen (1.5 sec.)
Toggle screen (1.5 sec.)
Motor load error
Power ON
if problem exist
Power OFF
Call for service
Wait 30 seconds
Printed in USA 12/20 © 2020
N/A
N/A
N/A
N/A
N/A
N/A