Intermec Shell 4.01 Standard – Startup Manual
TERMINAL SETUP, cont'd.
Changing the Setup
If you want to set up the printer or use any other of the facilities, you
should answer N (=No) to the "Select Application" prompt. The
following example illustrates how to change the printer's commu-
nication setup from 19,200 baud to 9,600 baud:
----------------
SHELL
SEL. APPLICATION
----------------
(Y / N):N
----------------
SHELL
SETUP
----------------
(Y / N):Y
----------------
SETUP FROM
TERMINAL
----------------
Reading printer setup, please wait.
If no change, press ENTER
To end terminal setup: enter QUIT (Q), or QUIT and SAVE (S)
CONTRAST,5
New value: (0-10) :
UART1,BAUDRATE,19200
New value: (1:300 2:600 3:1200 4:2400 5:4800 6:9600 7:19200) :6
Comment: You must specify the baudrate by a digit (1–7) according
to the displayed list of options and then press enter.
UART1,PARITY,NONE
New value: (1:NONE 2:EVEN 3:ODD 4:MARK 5:SPACE) :S
Comment: Enter Q to quit without saving, or S to save the new setup
and quit the Terminal Setup.
Are you sure? (Y / N):Y
Comment: As a safety measure, you must acknowledge your
command.
xf~xxff`xx~f`ffffffffffffffffffffxxxf`ff`ffffffffffffffffffffffffxx~fx
Comment: Since you have changed the communication para-
meters, the messages from the printer will become garbled. Reset
the communication setup in your terminal program according to
the printer's setup and press Enter.
17