Advertisement

Quick Links

Thorlabs Instrumentation
TXP5004
Operation Manual
2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TXP5004 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for THORLABS TXP5004

  • Page 1 Thorlabs Instrumentation TXP5004 Operation Manual 2017...
  • Page 2 Version: 3.1.5 Date: 31-Jan-2017 Item No.: M0009-510-101 Copyright © 2017 Thorlabs GmbH...
  • Page 3: Table Of Contents

    6 Maintenance and Service 6.1 Replacing the Line Fuse 6.2 Replacing the Internal Fuses 6.3 Troubleshooting 7 Appendix 7.1 Technical Data 7.2 Certifications and Compliances 7.3 Warranty 7.4 Copyright and Exclusion of Reliability 7.5 Thorlabs 'End of Life' Policy 7.6 Thorlabs Worldwide Contacts...
  • Page 4: Foreword

    Paragraphs preceeded by this symbol explain hazards that could damage the instrument and the connected equipment or may cause loss of data. Note This manual also contains "NOTES" and "HINTS" written in this form. Please read these advices carefully! © 2017 Thorlabs GmbH...
  • Page 5: General Information

    Prior to applying power to the TXP5004, make sure that the protective conductor of the 3 conductor mains power cord is correctly connected to the protective earth ground...
  • Page 6 Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Thorlabs GmbH is not responsible for any radio television interference caused by modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Thorlabs GmbH.
  • Page 7: Ordering Codes And Accessories

    · Windows 8.x (32-bit, 64-bit) For operation of the TXP5004, also an NI-VISA (version 5.4.1 or higher) is required. This NI- VISA engines comes with the Thorlabs GmbH TXP5004 installation software package, but can be downloaded also from National Instruments' website www.ni.com.
  • Page 8: Getting Started

    4. Operation Manual 5. Power Cord 2.2 Installing Software Note Do not connect the TXP5004 to the PC prior to software installation! Attention Exit all running applications on your PC as the installer may require a reboot of your PC during installation! The TXP software package contains: ·...
  • Page 9 2 Getting Started A user account control warning comes up: Allow the installation. Then follow the the screenshots below: © 2017 Thorlabs GmbH...
  • Page 10 TXP5004 © 2017 Thorlabs GmbH...
  • Page 11 This Windows Security message appears twice. You may be requested to restart your computer upon finishing software installation. Note If you are requested to restart your computer, please do so. Otherwise, the TXP software won't operate properly. © 2017 Thorlabs GmbH...
  • Page 12: Operating Elements Txp5004

    TXP5004 3 Operating Elements TXP5004 Front panel LED "ON" Mains switch USB-B connector Rear panel Ground connector Cooling fan AC power connector with line fuse © 2017 Thorlabs GmbH...
  • Page 13: First Steps

    In this position the TXP module is disabled! Correct position · Connect the power cord to your TXP5004 and switch it on. The green LED "Power ON" must light up. 4.1 USB driver installation Connect the TXP5004 to your computer using the USB cable provided with the unit.
  • Page 14: Txp Server Configuration

    ) or from the Windows Start button: At first use of the TXP Server, a configuration wizard is started. It is strongly recommended not to change the settings in the next appearing dialog boxes - just click "Next" to continue: © 2017 Thorlabs GmbH...
  • Page 15 4 First Steps Note For the Gateway Mode please see next section. Click "Finish" to start the TXP Server software. © 2017 Thorlabs GmbH...
  • Page 16 The TXP5004 is ready for operation now. Note Above procedure needs to be executed only once. Further connections of the TXP5004 to the PC will recall these setting, except other applications were installed, requiring COM ports or a different TXP5004 was used.
  • Page 17: Gateway Mode

    4 First Steps 4.3 Gateway Mode The PC that controls the TXP5004 via USB, can serve as a gateway to a local area network. This way, any other PC logged on to the same LAN can take over the control.
  • Page 18 Select from Windows button -> Programs the TXP Polarimeter Software: The TXP LS GUI starts up; click to "Connect" button: and enter the host name (or the IP address) of the USB control PC into the appropriate box and click OK: © 2017 Thorlabs GmbH...
  • Page 19 4 First Steps Then select the desired LS5 module and click OK: The TXP LS GUI connects to the module and is ready for use: © 2017 Thorlabs GmbH...
  • Page 20: Operating Instruction

    In order to maintain a proper air flow for internal cooling, unused TXP slots must be covered by blind modules! Make sure, that - the TXP5004 with inserted electronics module is switched on and connected to the PC via a USB2.0 cable. - the TXP Server is started and running (see icon in the task bar).
  • Page 21: Maintenance And Service

    6 Maintenance and Service 6 Maintenance and Service Protect the TXP5004 from adverse weather conditions. The TXP5004 is not water resistant. Attention To avoid damage to the instrument, do not expose it to spray, liquids or solvents! The unit does not need a regular maintenance by the user. It does not contain any modules and/or components that could be repaired by the user himself.
  • Page 22: Replacing The Line Fuse

    Attention To avoid fire hazard only the appropriate fuses must be used! · Switch off the TXP5004 and remove the power cable from the mains jack. Look at the back of the unit. · Open the cover of the fuse holder at the rear using a small screwdriver.
  • Page 23: Troubleshooting

    · The TXP Server starts and reports "There is no COM port available" Ø Did you connect your TXP5004 to a different USB port than before or are you using a different TXP5004? The COM ports are assigned to slots with a specific name on a specific USB port. If you change either the USB port or the TXP, the system needs to assign new COM ports to the found new hardware.
  • Page 24 Uninstall option and check the box "Delete the driver software for this device". Repeat this for all 4 ports. o Disconnect the TXP5004 from the USB port, reconnect it and make sure that the drivers are being installed now properly.
  • Page 25: Appendix

    Pollution Degree (indoor use only) Operation Altitude < 2000 m Warm-up Time (typ.) 10 min Weight (empty) 3 kg ) non-condensing All technical data are valid at 23 ± 5°C and 45 ± 15% rel. humidity (non condensing) © 2017 Thorlabs GmbH...
  • Page 26: Certifications And Compliances

    Compliance demonstrated with various TX Series light source and electrical modules installed Emissions, which exceed the levels required by these standards, may occur when this equipment is connected to a test object. Minimum Immunity Test Requirement Replaces Low Voltage Directive 73/23/EEC, amended by93/68/EEC © 2017 Thorlabs GmbH...
  • Page 27: Warranty

    For warranty repairs or service the unit must be sent back to Thorlabs GmbH. The customer will carry the shipping costs to Thorlabs GmbH, in case of warranty repairs Thorlabs GmbH will carry the shipping costs back to the customer.
  • Page 28: Copyright And Exclusion Of Reliability

    Thorlabs GmbH dealer or system installer. All rights reserved. This document may not be reproduced, transmitted or translated to another language, either as a whole or in parts, without the prior written permission of Thorlabs GmbH. Copyright © Thorlabs GmbH 2017. All rights reserved.
  • Page 29: Thorlabs 'End Of Life' Policy

    Waste treatment on your own responsibility If you do not return an “end of life” unit to Thorlabs GmbH, you must hand it to a company specialized in waste recovery. Do not dispose of the unit in a litter bin or at a public waste disposal site.
  • Page 30: Thorlabs Worldwide Contacts

    Email: europe@thorlabs.com Email: scandinavia@thorlabs.com France Brazil Thorlabs SAS Thorlabs Vendas de Fotônicos Ltda. 109, rue des Côtes Rua Riachuelo, 171 78600 Maisons-Laffitte São Carlos, SP 13560-110 France Brazil Tel: +33-970 444 844 Tel: +55-16-3413 7062 Fax: +33-811 38 17 48 Fax: +55-16-3413 7064 www.thorlabs.com...
  • Page 32 www.thorlabs.com...

Table of Contents