7.2 Failure Alerts

Clock Board Faults
Type
Error
F1
01
Initialization error - No master power board found.
02
Initialization error - No slave power board found.
03
General software error.
04
Communication error - The master power board does not respond in time or at all.
05
Communication error - The slave power board does not respond in time or at all.
06
Unknown model ID - The clock board does not support the model ID set on the
power board.
16
Crystal Oscillator fault. This can occur during baking with a lot of condensation.
18
10
Critical software/hardware fault.
11
12
13
14
15
17
19
20
21
39
Description & Possible Solution
Check model ID is set correctly for the model you are working on - refer pg. 35
Check harness connections to master power board
Replace master power board
Check model ID is set correctly for the model you are working on, refer pg. 35
Check the harness connections at the slave power board
Replace the slave power board
Try powering the oven off and on. If the problem persists, replace the clock
module
Check connection to master power board
If the problem persists, replace power board
Check connection to slave power board
If the problem persists, replace the slave power board
Turn product off and back on at the wall, check the model ID via technician
mode - refer pg. 35
If the problem persists, replace clock module and set the correct model ID -
refer pg. 35
Let the oven cool down and dry out. Then power the oven off and on.
If the problem persists, replace the clock module
Try powering the oven off and on. If the problem persists, replace the clock
module.