Controlled document: M-0002B
I N P R E S S T S
Revision: B
Issue Date: 30 August 2021
C on te nt s
1 USER GUIDE
1 Key Features
2 WARNING
3 CONTROLLER APPEARANCE
4 FUNCTIONS
5 OPERATING INSTRUCTIONS
5 Enter Setup Mode
6 Change Date and Time
6 Change Pressure Setpoint
6 Change ALarm Setpoint
7 Enable / Disable Buzzer
7 Change Alarm DELAY Settings
7 Change Service Reminders
8 Calibrate Zero Sensor
8 Reset Data Log
8 Test Inputs Option
9 TECHNICAL DETAILS
9 Map of Functions
11 General Arrangement
12 Connector Pinout Details
14 Installation
15 Fan Speed Control Output
15 Mounting
15 Supply Power
15 Calibration
15 Control Override
16 Data Logging Information
20 BREATHESAFE WARRANTY
21 CONTACT US
© BREATHESAFE 2021
FUNCTIONS
AUTOMATIC CABIN PRESSURE
The INPRESS TS is an intelligent pressuriser controller that monitors
the pressure difference from inside to outside of the cabin. It controls
the speed of the motor to maintain a set pressure difference.
LOW PRESSURE ALARM
If the cabin pressure falls below the alarm setpoint, INPRESS TS will
wait the designated delay time before alarming user.
The alarm will sound, and LOW-PRESSURE WARNING will flash on
screen in red lettering. Press the ALARM button to mute the alarm.
At the same time as this alert is sounding, the fan power will increase
to maximum to keep operator as safe as possible.
ALARM DELAY
Controlled document:
There is a designated delay time between the TS measuring low
Issue Date:
pressure and sounding the delay. This gives allowances in time for
small changes like opening window briefly. The amount of delay can
be changed in settings.
SERVICE REMINDERS
The INPRESS TS has automatic reminders for servicing of filter system.
The default is 500 runtime hours, but can be altered in settings.
PAGE 4
www.breathe-safe.com.au
DATA LOGGING
By default, the BreatheSafe INPRESS TS unit starts data logging as
soon as power is applied. This feature cannot be stopped or disabled.
Data logging records time, date, pressure reading, and any alarms
activated during operation.
LIGHT SENSOR
The light sensor automatically adjusts screen brightness for operator
safety and minimised distraction
GRAPHIC DISPLAY OF PRESSURE CHANGE
A graphic display is available for a visual representation of the
pressure inside cabin over time since turned on.
Graph Screen