CONNECTOR PINOUT DETAILS

Controlled document:
Issue Date:
Please do not scale
PAGE 12
www.breathe-safe.com.au
ITEM
PIN
DESIGNATION
1
Pin 1
24V Positive Supply
2
Pin 2
CAN H Option
3
Pin 3
CAN L Option
4
Pin 4
Serial Transmit RS232 Door load
5
Pin 5
Motor Control Volts Out
6
Pin 6
Alarm + Output
7
Pin 7
Temp Sensor
8
Pin 8
No Connection
9
Pin 9
Serial Receive RS232
10
Pin 10
Door Input (+)
11
Pin 11
Window Input (+)
12
Pin 12
0V Negative Ground