3 Specific installer safety instructions

FTXP-N
Daikin room air conditioner
4P518023-14L – 2022.06
Always observe the following safety instructions and regulations.
Unit installation (see
"6 Unit
WARNING
Installation shall be done by an installer, the choice of materials and installation shall
comply with the applicable legislation. In Europe, EN378 is the applicable standard.
CAUTION
For walls containing a metal frame or a metal board, use a wall embedded pipe and
wall cover in the feed-through hole to prevent possible heat, electrical shock, or fire.
Piping installation (see
CAUTION
Piping and joints of a split system shall be made with permanent joints when inside
an occupied space except joints directly connecting the piping to the indoor units.
DANGER: RISK OF BURNING/SCALDING
CAUTION
Incomplete flaring may cause refrigerant gas leakage.
Do NOT re-use flares. Use new flares to prevent refrigerant gas leakage.
Use flare nuts that are included with the unit. Using different flare nuts may
cause refrigerant gas leakage.
Electrical installation (see
DANGER: RISK OF ELECTROCUTION
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
All wiring MUST be performed by an authorised electrician and MUST comply
with the applicable legislation.
Make electrical connections to the fixed wiring.
All components procured on-site and all electrical construction MUST comply
with the applicable legislation.
3
Specific installer safety instructions
|
4
installation" [
 20])
4
"7 Piping
installation" [
"8 Electrical
installation" [
 29])
4
 34])
Installer reference guide
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxp60n2v1bFtxp50n2v1b

Table of Contents