Table Of Contents; About This Document; Specific Installer Safety Instructions - Daikin Sky Air Active Series Installation Manual

Hide thumbs Also See for Sky Air Active Series:
Table of Contents

Advertisement

Table of contents

3.1
Outdoor unit...............................................................................
3.1.1
4.1
Preparing the installation site ....................................................
4.1.1
4.2
Opening and closing the unit.....................................................
4.2.1
To open the outdoor unit.............................................
4.2.2
To close the outdoor unit ............................................
4.3
Mounting the outdoor unit..........................................................
4.3.1
To provide the installation structure ............................
4.3.2
To install the outdoor unit............................................
4.3.3
To provide drainage ....................................................
4.3.4
5.1
Connecting the refrigerant piping ..............................................
5.1.1
5.2
Checking the refrigerant piping .................................................
5.2.1
Checking refrigerant piping: Setup..............................
5.2.2
To perform a leak test ................................................. 10
5.2.3
To perform vacuum drying .......................................... 10
6.1
About electrical compliance....................................................... 10
6.2
6.3
Specifications of standard wiring components .......................... 11
6.4
7.1
About charging refrigerant......................................................... 12
7.2
About the refrigerant.................................................................. 13
7.3
Completely recharging refrigerant ............................................. 13
7.3.1
7.3.2
7.3.3
Charging refrigerant: Setup......................................... 14
7.3.4
To completely recharge refrigerant ............................. 14
7.4
To fix the fluorinated greenhouse gases label........................... 14
8.1
To insulate the refrigerant piping............................................... 14
8.2
9.1
Checklist before commissioning................................................ 15
9.2
To perform a test run................................................................. 15
9.3
Error codes when performing a test run .................................... 16
11.1
Service space: Outdoor unit ...................................................... 17
11.2
Piping diagram: Outdoor unit..................................................... 18
11.3
Wiring diagram: Outdoor unit .................................................... 19
1

About this document

Target audience
Authorised installers
AZAS100~140MUV/Y
Sky Air Active-series
4P743507-1 - 2023.08
INFORMATION
This appliance is intended to be used by expert or trained
users in shops, in light industry and on farms, or for
commercial use by lay persons.
3
Documentation set
3
This document is part of a documentation set. The complete set
5
consists of:
5
▪ General safety precautions:
5
▪ Safety instructions that you MUST read before installing
5
▪ Format: Paper (in the box of the outdoor unit)
5
▪ Outdoor unit installation manual:
5
6
▪ Installation instructions
6
▪ Format: Paper (in the box of the outdoor unit)
6
▪ Installer reference guide:
7
7
▪ Preparation of the installation, reference data, ...
7
▪ Format: Digital files on https://www.daikin.eu. Use the search
7
function
to find your model.
8
Latest revisions of the supplied documentation may be available on
8
the regional Daikin website or via your dealer.
8
The original instructions are written in English. All other languages
8
are translations of the original instructions.
9
Technical engineering data
9
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
10
▪ The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
2
Specific installer safety
12
instructions
Always observe the following safety instructions and regulations.
Installation site (see
13
WARNING
Follow the service space dimensions in this manual for
correct installation of the unit. See
requirements of the outdoor
14
WARNING
The appliance shall be stored in a room without
continuously operating ignition sources (example: open
15
flames, an operating gas appliance or an operating electric
heater).
CAUTION
Appliance NOT accessible to the general public, install it in
16
a secured area, protected from easy access.
17
This unit, both indoor and outdoor, is suitable for
installation
in
environment.
Opening and closing the unit (see
unit" [ 4  6])
DANGER: RISK OF BURNING/SCALDING
DANGER: RISK OF ELECTROCUTION
Table of contents
"4.1 Preparing the installation
"4.1.1  Installation site
unit" [ 4  5].
a
commercial
and
light
"4.2 Opening and closing the
Installation manual
site" [ 4  5])
industrial
3

Advertisement

Table of Contents
loading

Table of Contents