IBM 3534-F08 Installation And User Manual page 41

Totalstorage san switch
Hide thumbs Also See for 3534-F08:
Table of Contents

Advertisement

c. Repeat steps 3a on page 18 - 3b on page 18 for the second inner rail on the
other side of the switch chassis.
4. Optional step: If desired, install the right rack mount bracket 2 and the left
rack mount bracket 3 on the switch chassis. These brackets secure the switch
to the rack as shown in Figure 8.
6
3
Figure 8. Mounting the moving portion of the slide and the mounting brackets to the switch
a. Position the left rack mount bracket at the left front corner of the switch
chassis, so that the two holes in the bracket align with the two threaded
holes in the switch chassis.
b. Attach the bracket using two of the 8-32 x 3/16 in. zinc screws 6 .
Attention:
Using screws longer than 3/16 in. can damage the switch.
c. Repeat steps 4a - 4b for the right rack mount bracket on the right front
corner of the switch chassis.
5. Attach all four of the 3-hole rack mounting brackets 4 as shown in Figure 9 on
page 20.
1
Offset holes for
9306 Netfinity racks
Front
Chapter 2. Installing and configuring the 3534 Model F08
Sj000348
19