Checking the CDI unit
1. Connect the digital circuit test leads to
the orange and black leads from the CDI
unit.
2. Measure the CDI unit output peak volt-
age. If the measurement is below specifi-
cation, check the lead, and measure the
peak output voltages of the pulser and
charge coils.
Digital circuit tester: 90890-03174
Peak voltage adapter B:
90890-03172
CDI unit output peak voltage:
Orange-ground lead
r/min
Cranking
DC V
155
NOTE:
Replace the CDI unit if output peak voltages
of the pulser and charge coils are on or above
specification and the CDI unit output peak
voltage is below specification.
6D45F11
B
O
B
O
6D480170
Loaded
1,500
3,500
170
170
Ignition and ignition control system
Checking the oil pressure warning
lamp
1. Disconnect the connector from oil pres-
sure switch.
2. Start the engine, then ground the oil pres-
sure switch lead.
3. Check the lamp comes ON. Replace if
necessary.
1
2
3
4
6D450040
5
6
6D480175
7
8
9
8-10