Module Specifications
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table B-2
Table B-2
Description
Dimensions
(HxWxD)
Weight
Power supply 845-W AC input for each power supply
Airflow
1. RU = rack unit; 1 RU = 1.75 inches (4.45 cm)
2. lfm = linear feet per minute
3. cfm = cubic feet per minute
Table B-3
the chassis) and the switching and services modules.
Module Specifications
This section provides the Cisco MDS 9200 Series module specifications.
Table B-3
Description
Environmental Requirements
Temperature, certified for operation 32 to 104°F (0 to 40°C)
Temperature, designed and tested
for operation
Temperature, ambient nonoperating
and storage
Humidity (RH), ambient
(noncondensing) operating
Altitude, certified for operation
Cisco MDS 9200 Series Hardware Installation Guide
B-2
lists the physical specifications for the Cisco MDS 9200 Series.
Physical Specifications for the Cisco MDS 9200 Series
Specification
5.25 x 17.5 x 22.75 in. (13.3 x 44.5 x 57.8 cm)
Chassis requires 3 RU
Chassis depth including cable guide is 27.75 in. (70.3 cm).
Chassis only: 31 lb (14.1 kg).
Chassis configured with one supervisor module, fan module, and
two power supplies: 53.3 lb (24.3 kg).
2
300 lfm
through system fan module, or 80 cfm
switching, or services module. Total of 160 cfm if slot 2 is filled.
Spacing requirements:
•
If installed in a cabinet, a minimum of 2.5 in. (6.4 cm) is
required between the chassis air vents and the cabinet walls.
If installed in an open rack (no side panels), the horizontal
•
distance required between the chassis and any devices that
exhaust air towards the chassis is a minimum of 6 in.
(15.2 cm), and the distance required between the chassis air
vents and any walls is a minimum of 2.5 in. (6.4 cm).
lists the specifications for the Cisco MDS 9200 Series supervisor module (which is fixed in
Cisco MDS 9200 Series Module Specifications
1
.
Specification
32 to 130°F (0 to 55°C)
-40 to 167°F (-40 to 75°C)
10 to 90%
0 to 6500 ft (0 to 2000 m)
Appendix B
Technical Specifications
3
per supervisor,
OL-19588-01