Fire Ventilation Zone
INSTALLATION MANUAL
Fire Dampers
WKP-P
SMAY Sp. z o.o. / ul. Cieplownicza 29 / 31-587 Krakow
Phone: +48 12 680 20 80 / E-mail: info@smay.eu
www.smay.eu
Version: 1.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WKP-P and is the answer not in the manual?

Questions and answers

Summary of Contents for SMAY WKP-P

  • Page 1 Fire Ventilation Zone INSTALLATION MANUAL Fire Dampers WKP-P SMAY Sp. z o.o. / ul. Cieplownicza 29 / 31-587 Krakow Phone: +48 12 680 20 80 / E-mail: info@smay.eu www.smay.eu Version: 1.5...
  • Page 2 2434 SMAY Sp. z o.o. 2434-CPR-0015 PN-EN 12101-8:2012 Smoke control damper Multi and single compartment Type: WKP-P Nominal activation conditions / sensitivity: Automatic activation - passed Closure/opening during test at correct time and in allowable time Response delay/closure time: Automatic activation - passed...
  • Page 3: Table Of Contents

    Version: 2.3 SMAY reserves the right to modify this document. Contents Device installation instructions ................4 Installation Technology – Rigid Wall Structure ............4 Installation Technology – Light wall structures ............8 Installation Technology – Wall Structures of High Thickness ........ 9...
  • Page 4: Device Installation Instructions

    It is acceptable to use WKP-P dampers in walls with other fire resistance rating, but in this case it should be kept in mind that EI fire resistance rating of the whole WKP-P damper installation is equal to the fire resistance rating of the lowest rated element of the system.
  • Page 5 Operation and Maintenance Manual WKP-P Mortar, cement mortar, lime- cement mortar or concrete Rigid wall structure Fig. 1. Dimensions of the mounting hole for WKP fire dampers in rigid wall structures with horizontal and vertical axis of rotation of the baffle. C parameter is presented in the Table.
  • Page 6 Operation and Maintenance Manual WKP-P Fig. 2. The way of installing WKP-P fire dampers in rigid wall structures. Axis of the baffle shall coincide with the axis of the wall. Version: 2.3 Page 6 of 10 Date: 19.07.19...
  • Page 7 Operation and Maintenance Manual WKP-P Rigid wall structure Mortar, cement mortar, lime-cement mortar or concrete Fig. 3. The way of installing WKP fire dampers with KST grilles in rigid wall structures. Version: 2.3 Page 7 of 10 Date: 19.07.19...
  • Page 8: Installation Technology - Light Wall Structures

    Operation and Maintenance Manual WKP-P Installation Technology – Light wall structures Make a hole in the wall – 310 mm greater than the dimension B and 180 greater than dimension H, i.e. B+310 and H+180. Make a frame of two layers of GKF boards with 15 mm thick and a width corresponding...
  • Page 9: Installation Technology - Wall Structures Of High Thickness

    1.3 Installation Technology – Wall Structures of High Thickness In rigid wall structures of 125 mm or lower thickness, WKP-P fire dampers are mounted in such a way that the axis of the damper body approximately coincides with the axis of the wall.
  • Page 10: Installation Technology - Masking Grille

    Fig. 6. Installation technology of masking grille for WKP-P Version: 2.3 Page 10 of 10...