The VM5094 has a 9-inch (230 mm) screen, the VM5124 has a 12-inch (305 mm) screen and the VM5154 has a 15-inch (381 mm) screen. These compact units are housed in a rugged yet attractively-styled cabinet with a convenient carrying handle. Both units are dual scanning (EIA and CCIR) and incorporate a universal power supply that accommodates 120 or 230 VAC.
Installation Unpacking and Inspection All Vicon equipment is inspected and tested before leaving the factory. It is the carrier’s responsibility to deliver the equipment in the same condition in which it left the factory. Inspection for Visible Damage Immediately inspect the cartons upon delivery. On all copies of the carrier’s freight bill, make a note of any visible damage.
Page 7
Installation with multiple monitors (Monitor N is last monitor in the system) Monitor 1 Monitor N 75 ohm switch 75 ohm switch Camera (OFF) (ON) Coaxial cable Figure 1 Typical Video Installations Installation • • 3 XX103 Rev 902 VM5094/VM5124/VM5154 High-Resolution Monitors...
The switch should be set to OFF for loop-through configuration and to ON when video signal is terminated at the monitor. AC Power Cord – Provides input power to unit when plugged into an outlet of appropriate voltage. 4 • • Operation XX103 Rev 902 VM5094/VM5124/VM5154 High-Resolution Monitors...
Page 9
Figure 2 Front and Rear Panel Controls Operation • • 5 XX103 Rev 902 VM5094/VM5124/VM5154 High-Resolution Monitors...
Geometric distortion of the picture to the left or right Maintenance The VM5094, VM5124 and VM5154 require no maintenance except the occasional cleaning of the cabinet and screen. Some common household aerosol sprays, cleaning agents, solvents or polishes may cause damage to the cabinet finish.
Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
Coaxial Cable Recommendations Caution: Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.
Power: 3-conductor removable line cord with grounding plug; a 120 VAC and 230 VAC line cord is supplied. Video In/Out: BNC. Radio Frequency Emission Rating: FCC Class A. Safety Standard: UL 2044. Technical Information • • 9 XX103 Rev 902 VM5094/VM5124/VM5154 High-Resolution Monitors...
Page 14
14° to 122° F (-10° to 50° C). Operating Humidity Range: 20 to 80% relative, noncondensing. Storage Temperature Range: -20° to 140° F (-29° to 60° C). Storage Humidity Range: 0 to 85% relative, noncondensing. 10 • • Technical Information XX103 Rev 902 VM5094/VM5124/VM5154 High-Resolution Monitors...