When the results of check item (19) are
"33 or 23 or 13 or
(Detection of HPD is OK / Detection of RXSENSE is OK )
Checking the EDID register. (HDMI ZONE2 OUT)
Check item(20).
Check the Monitor EDID :
① Unplug the AC cord. Plug the AC cord into a power outlet.
② Send the transmission command "m_3" from Termite.exe.
Are the first eight bytes of the returned value "00FFFFFFFFFFFF00"?
YES
3.3V
TMDS Signal
TMDS
Example of waveform in check ① Example of waveform in check ②
Check item(21).
Checking the TMDS :
Check the TMDS waveform at the following test
point.
ZONE2
YES
NO
Check for a short circuit in the TMDS line.
If there is no problem, the HDMI Switch-
er1 (U1003) is faulty.
Replace with a new device.
HDMI Switcher1 (U1003) is faulty.
Replace with a new device.
Recheck from
check item (3).
If it does not work, replace the PCB.
03"
NO
less than 100KHz
5V
5V
This diagram shows an example of the DDC communica-
tion waveform.
-The high level voltage is 5V.
-The frequency of the DDC CLK is 100 KHz or less.
Check at each test point.
Check item(22).
Check the communication :
Do "CK" and "DA" indicate (5V) at the test point
near HDMI output connector (N1030)?
ZONE2
DDCSCK
DDCSDA
YES
NO
Check for a short circuit in the DDC line.
If there is no problem, the HDMI Switch-
er1 (U1003) is faulty.
Replace with a new device.
HDMI Switcher1 (U1003) is faulty.
Replace with a new device.
Example
m_3
The first eight bytes are nor-
mally "00FFFFFFFFFFFF00".
The correct resistor value can-
not be checked if the AVR and
TV are not connected by HDMI.