Download Print this page

Denon AVR-X3300W Service Manual page 168

Integrated network av receiver
Hide thumbs Also See for AVR-X3300W:

Advertisement

Error
DPMS Update Error
Details of Error code
Code
Display
Failed to start up Sub in
62
Power On sequence during
Update Error**62
Update.
Write Enable Latch Bit not
80
set in Read after issuing the
Update Error**80
"WREN" command.
Update Error**81 Block Erase failed in Read after
81
issuing the "BE" command.
Update Error**82 No Update Packet received
82
from CY920 (Time Out).
Abnormal data in Update
83
Packet received from CY920
Update Error**83
(CRC Error).
Abnormal data in Update
84
Packet received from CY920
Update Error**84
(PacketNoError).
Update Error**85 Setup failure of the XModem
85
transfer method.
Mismatched Check Sum in
86
Check Sum comparison after
Update Error**86
rewriting.
Update Error**A0 IP Address acquisition failure
A0
(AutoIP).
Update Error**A1 IP Address acquisition failure
A1
(Time Out).
Update Error**A2 DPMS login incorrect notifica-
A2
tion.
Update Error**A4 DPMS connection failure
A4
notification.
Error notification received
A6
while requesting the Firm-
Update Error**A6
ware Info.
Remedies
Unplug and reconnect the AC plug, and
try again.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
Unplug and reconnect the AC plug, and
try again.
Unplug and reconnect the AC plug, and
try again.
Unplug and reconnect the AC plug, and
try again.
Unplug and reconnect the AC plug, and
try again.
If the same error occurs even when it is
retried, the device may be malfunction-
ing.
Unplug and reconnect the AC plug, and
try again.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
Unplug and reconnect the AC plug, and
try again.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
168
Error
DPMS Update Error
Details of Error code
Code
Display
Update Error**A7 Time Out while obtaining
A7
Firmware information.
Error(NG) notification received
AE
while requesting Firmware
Update Error**AE
Download.
Error(Connect failure) notifica-
B0
tion received while request-
Update Error**B0
ing Firmware Download.
Update Error**B1 Error in Firmware Download
B1
(Time Out).
Update Error**B2 Error notification received af-
B2
ter rewriting the CY920 Firm.
Update Error**B3 Error in Firmware Update
B3
(Time Out).
Update Error**B4 Failed to transit to Boot
B4
Loader Mode.
Update Error**B5 Failed to transit to Application
B5
Mode.
---Checking the Firmware Version After the Update---
After updating the firmware, check the version.
See
"1. Version Display
Mode"
Remedies
Unplug and reconnect the AC plug, and
try again.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
Check the network connection, Unplug
and reconnect the AC plug, and try
again.
Unplug and reconnect the AC plug, and
try again.
Unplug and reconnect the AC plug, and
try again.
Unplug and reconnect the AC plug, and
try again.
Unplug and reconnect the AC plug, and
try again.

Advertisement